5.3.1 Drinking Water Tool Kit Disinfection
It is strongly recommended that all tools are disinfected prior to use. Disinfecting tools will reduce the
risk of cross-contamination between different job sites. Failure to disinfect tools could lead to cross-
contamination. Contaminated water may cause sickness, serious personal injury and/or death.
5.3.1.1 Pressure Gauge Disinfection Procedure
All pressure gauges MUST be disinfected prior to use in order to avoid cross-contamination.
When performing this procedure, handle the disinfection solution with care. It is recommended that
protective gloves be worn to avoid skin contact with the chlorine based solution. Failure to follow these
guidelines may lead to skin irritation and/or damage to clothes.
Pressure gauge and brass gauge adaptor
The pressure gauge setup consists of two components: the pressure gauge and the brass gauge adaptor.
These are threaded together using Teflon® tape, as shown below. Each step in the disinfection procedure
is demonstrated in the accompanying figures.
Step 1 - Separate the pressure gauge from the
gauge adaptor.
Step 2 - Place and soak the gauge adaptor in
Household chlorine bleach for 5 minutes. Note the
brass adaptor will tarnish. This is acceptable.