Maytag MWF4200AWS Technical Information Page 46

  • Download
  • Add to my manuals
  • Print
  • Page
    / 135
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 45
4-14
When treating surface water sources, the MAYTAG External Prefilter is required. Failure to provide
this level of prefiltration may lead to System damage endangering the homeowner, potentially causing
injury and in serious cases even death.
4.6.2 MAYTAG Controllers
The main function of the MAYTAG System Controller is to perform automatic daily cleaning of the
System. In order to address the different water types, sources and qualities, a series of System Controllers
were developed. All are listed and described below.
4.6.2.1 Base Controller
25
(included with MWF 4100 AWS and MWF 4200 AWS)
The Base Controller has been designed for use on municipally treated, well, and cistern sources with
turbidities up to 1.0 NTU (turbidity units). The Base Controller provides a daily cleaning procedure by
performing a number of front / backpulse cycles. As a result, cleaning effectiveness for surface waters and
for sources that have turbidity levels greater than 1.0 NTU is limited.
Figure 4.15 - MAYTAG Base Controller
The Base Controller, shown in Figure 4.15, can be programmed to perform a number of different Front /
Backflush sequences depending on the quality of the water within the constraints given below. This
Controller uses 2 “AA” batteries to save the program settings during power outages. It also contains a fuse
to prevent internal damage during lightning events or other power surges.
4.6.2.1.1 Base Controller Application Summary
Table 4.1 - Base Controller Applications
Program Water Quality Requirements,
Source Water Turbidity (NTU)
Household Water Use Household
Occupants
26
#1 <0.5 Up to 1135 LPD (300 USgpd) Up to 4 people
#2 <0.5 Peaks to 1.0NTU, <5% of time Up to 1135 LPD (300 USgpd) Up to 5 people
#3 <0.5 Peaks to 1.0 NTU, <5% of time Up to 1510 LPD (400 USgpd) Up to 6 people
25
Base Controller has not been performance tested and certified by NSF.
26
Based on 350 litres (93 USgal) per day per capita.
Page view 45