2-4
A bypass system is not required for proper operation of the MAYTAG Whole Home Water Filtration
System, however some local plumbing codes may require a bypass. If the System is to be equipped with a
bypass, this procedure below may be followed to provide water in an emergency or System malfunction.
1
Bypass Procedure
1. Close the Inlet and Outlet ball valves (turn handles clockwise). Ball valves are in the closed position
when the handle is positioned perpendicularly to the water pipe.
2. Open Bypass Valve (turn handle counter-clockwise).
3. Unplug the controller.
4. To return to filtered water service;
o close bypass valve (turn handle clockwise)
o open inlet and outlet valves (turn handles counter-clockwise)
o plug in the controller.
1
System malfunction would include a possible water leak or failed integrity test.
Comments to this Manuals