5-13
Table 5.1 Backpulse Tank Pressure Chart
Installation Location Backpulse pressure
Municipal 207 kPa (30 psig)
Well (20 psig low – 40 psig high cutoff) 140 kPa (20 psig)
Well (30 psig low – 50 psig high cutoff) 207 kPa (30 psig)
Well (40 psig low – 60 psig high cutoff) 207 kPa (30 psig)
Do not pressurize the System Backpulse Tank greater than 35 psig. Higher pressures may cause the
Backpulse tank bladder to burst, leading to ineffective daily cleaning of MAYTAG Whole Home Water
Filtration System. Ineffective cleaning of the MAYTAG Whole Home Water Filtration System can
greatly reduce the life of the System and in some cases lead to sickness and/or death.
5.4.5 Positioning and Pipe Assembly
Step 1 Position the System approx. 6” from
where the piping will be. Drill a 3/8” hole through
the feet of the backpulse stand.
Step 2 Using the supplied screws and anchors,
secure the System to the floor. Use each of the ¼”
screws for wooden floors and lag bolts for concrete
floor. If the System is to be installed on a heated
floor, use a 2’ x 2’ patio stone.
Step 3 Check to see if the System is level.
Step 4 Insert the supplied shims as required
under the feet, between the bolts, to help level the
System.