Maytag MWF4200AWS Technical Information Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 135
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
2-2
To avoid System damage: Ensure that a Stainless Steel Prefilter or Carbon Prefilter is in place
during operation of the System. In the absence of an internal Prefilter, abrasive damage to the
System may occur. A damaged System may permit contaminated water to enter the household
distribution system causing illness. Irreversible and premature fouling of the System may also
occur resulting in System replacement at the owner’s expense.
2.3 Service and Maintenance Safety
To avoid electric shock: Disconnect the AC power from the MAYTAG Whole Home Water
Filtration System before servicing the controller; do not remove the controller cover while System
is in use. Only MAYTAG Services Qualified Service Technicians should attempt to service the
controller.
Important: The MAYTAG Whole Home Water Filtration System must be kept in a wetted
condition. Once installed or during service and maintenance activities, do not allow the System to
sit completely drained for extended periods (>12 hours). Failure to do so may damage the System
and cause contaminated water to enter the household for consumption.
The MAYTAG Whole Home Water Filtration System must be kept wet at all times after installation.
Failure to do so may cause the System to dry and become damaged, which may lead to personal injury,
and/or physical damage and will void any warranty.
2.4 Winter Storage
The MAYTAG Whole Home Water Filtration System will be damaged if frozen. The System must be
winterized according to the Winterization Procedure 6.2 by a MAYTAG Services Qualified Service
Technician.
The MAYTAG Whole Home Water Filtration System must be;
winterized prior to temperatures falling below 0°C (32°F). Failure to do so may cause the System to dry,
freeze and become damaged, which may lead to personal injury, and/or physical damage and will void
any warranty.
2.5 Other Safety Recommendations
Do not plug in the Controller transformer if there is water on the electrical wiring or the power
supply.
Always shut off water flow and release water pressure before cleaning or maintaining the System.
The System is intended for indoor use only. The power supply and controller must not be exposed
to weather elements.
A MAYTAG Services Qualified Service Technician must perform an Integrity Test, Procedure in
section 5.5.4, at least once a year.
Page view 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 134 135

Comments to this Manuals

No comments