5-24
Do not use extension cords to hook transformer to power source. Doing so will increase the
risk of electrical shocking if the wiring is exposed to water. Personal injury and/or property
damage may result.
Step 5 – Set up the controller using the procedure outlined below.
Table 5.2 MWF 4100 AWS and MWF 4200 AWS Controller Program Selection
Base Controller – MWF 4100 AWS and MWF 4200 AWS Controller Program Settings
Controller-
Program
Recommen
ded
household
occupancy
(persons)
Source
water
turbidity*
*
(NTU)
Daily household
water
consumption
No.
Flushes
per
cycle
No.
tank
drains
per
cycle
Flush water
used per day
(flow at
7USGAL/min)
Base-Prg 1 Up to 4 <0.5 300Usgal/d
(1135L/d)
2 -- 14Usgal/d
(53L/d)
Base-Prg 2 Up to 4 <0.5Peaks
to 1.0NTU,
<5% of
time
300Usgal/d
(1135L/d)
3 -- 21Usgal/d
(80L/d)
Base-Prg 3 Up to 6 <0.5 Peaks
to 1.0NTU,
<5% of
time
400Usgal/d
(1510L/d)
4 -- 28Usgal/d
(106L/d)
**If turbidity peaks are higher than those listed, consult MAYTAG Technical Assistance at 1-800-
756-2926
button (1) to toggle through
the modes.
2. MANUAL FLUSH: press next (1) until
manual is flashing. Press manual flush (5)
and hold. If held longer than 10 seconds, drain
solenid remains open. Toggle solenoid closed
by pressing manual flush (5) once.
3. SETTING TIME OF DAY: press next (1)
until set time appears. Press enter (2). Use
up/down arrows (3, 4) to set time of day. Press
enter (2) to set.
4. SET TIME OF FLUSH: press next (1) until
start time appears. Press enter (2). Use
up/down arrows (3, 4) to set time of flush.
Press enter (2) to set.
5. SETTING PROGRAM CHOICE: press next
(1) until program appears. Press enter (2).
Use up/down arrows (3, 4) to select program
choice. Press enter (2) to set.
See Table 5.2 for Base Controller Programming
Choices
2
3