Step 11 Ensure the System Cap is tightened
properly.
Step 12 Open in the inlet valve half way to allow
water to enter and pressurize the System.
Step 13 As the System begins to fill with water,
air will be heard escaping from the air vent.
When the System is full, no more air will be heard
escaping. Inspect for leaks.
Step 14 When no further air exits the System,
open the inlet valve completely. Note If a leak is
observed, the cap was not properly installed or the
o-ring is damaged or dirty. Return to step 1 if any
leaks are detected.
Step 15 Once no leaks are present after filling
and pressurizing, allow the System to soak for 60
minutes. This will allow the sanitizing solution
time to distribute itself throughout the entire
System.
Step 16
Flush the System using the controller.
See section 5.4.7.3 for the Base Controller and
section 5.4.8.3 for the Advanced Controller.