6-20
Step 7 Pull the internal prefilter straight up and
out of the System and drip dry to remove excess
water. If not reusing, place into garbage bag and
dispose. If reusing or cleaning, place on a clean
surface.
Step 8 Inspect the prefilter spigot, located inside
the internal prefilter housing, and remove any
debris if necessary.
Step 9 Partially fill the System (with the System
Cap off) by opening the inlet valve partially to
allow water to fill the System. Continue to fill
until the prefilter housing is between ¼ and ½ full.
This will remove any remaining air pressure in the
System.
Step 10 Pour 250mL of 12% unscented chlorine
bleach or 500mL of 5% or 6% unscented chlorine
bleach into the prefilter housing as illustrated. Be
careful not to allow its contents to come in contact
with any skin or clothing.
NOTE: Filling too quickly, may lead to trapped air that may cause bubbling and splashing.
If this does occur, close the Inlet valve slightly to slow the flowrate into the System. After
filling to the appropriate level, close the Inlet valve.
NOTE: Chlorine bleach must be a new bottle (within 3 months). The effective
concentration is reduced in an open bottle over time.