5-14
Step 5 Make a final inspection to confirm that
the System is level.
Step 6 Tighten the bolts to secure the System to
the floor.
Step 7 Assemble the inlet and outlet devices.
Ensure that all threads are fitted with Teflon
tape. Attach the inlet device to the System
housing and the outlet device to the backpulse
tank.
Step 8 For the surface water systems (MWF
4300 AWS), a normally opened solenoid valve
must be installed on the inlet assembly. The
External Prefilter must also be installed between
the normally opened solenoid valve and the inlet
ball valve (refer to Figure 5.3 in section 5.2.2) and
mounted on a wall.