8-1
8 Troubleshooting
The following section will help diagnose some of the problems that might occur with the MAYTAG
Whole Home Water Filtration System.
“Area” Problem/Situation Correction/Action
General A part is missing. Most standard hardware parts are available at the
local hard ware store or call MAYTAG for a
MAYTAG Whole Home Water Filtration System
replacement part.
System leaks water. Cap is not properly tightened.
O-ring is not clean or intact.
O-ring is not in place.
Connections are not tight.
Connections were too tight and part broke.
Water is not adequately drained from System prior
to removing cap.
Teflon tape not used on thread.
Checking
Backpulse
Tank Pressure
Pressure is too high. Release some of the pressure until the desire
pressure is reached.
The pressure is too low. Add more pressure using a compressor or hand
pump.
There is no pressure in the
backpulse tank prior to adding
pressure.
All tanks are shipped with approximately 35 psi.
Repressurize tank and monitor for leak. Replace if
leaking.
Connecting
Piping
Assemblies
Threads are cross-threaded. Replace the parts if possible. Add more Teflon
tape and slowly thread the two parts together to
attempt to fix the problem. Be extremely careful
with future assemblies.
A leak results. Tighten connection.
Loosen connection that is too tight.
No Teflon tape, reinstall part using Teflon tape.
Air Vent Water spouts from top. Air relief port is not capped.
Air vent is faulty.
No water is flowing through
System.
Black air relief port cap must be loosened to 1 ½
turns (open).
Removal of
Cap
Can not remove cap. System may be pressurized. Turn off inlet valve
and drain System using controller.
External
Prefilter
Does not drain fast enough. Press and hold the red button on the top of the
housing to allow air to enter the housing and drain
more quickly.
Water is leaking from the
bottom.
Close the valve.