6-17
serious cases even death.
Chlorine bleach must be less than 3 months old. The active percentage reduces with time.
To avoid sending sanitizing solution into household hot water distribution system, do not turn on hot
water until sanitizing procedure is complete. Sanitizing solution in the water supply may irritate the skin
or cause illness if ingested.
MAYTAG has developed a strategy to ensure sanitary installation and maintenance procedures and to
extend the life of the MAYTAG Whole Home Water Filtration System through periodic maintenance
cleaning activities. Two different cleaning solutions have been selected and thoroughly tested to provide
these important System features. One is the MAYTAG MC1 Cleaning Solution and the other is any
standard, unscented household chlorine bleach.
MAYTAG Solution Applications MAYTAG Part #
MAYTAG MC1
Cleaning Solution
Municipal and Well water maintenance cleaning 67500024
6.4.1 Integrity Test
An annual integrity test is required in order to validate the System limited warranty.
See section 5.5.4 for the Integrity Test Procedure.
After the integrity test is complete:
Step 1 Check the backpulse tank pressure using
a digital gauge. See section 5.4.4 for Backpulse
tank pressure guide.
Step 2 If backpulse tank pressure is not at the
required pressure, use a hand pump or compressor
to pressurize the tank to the required pressure. See
Section 5.4.4.