Step 1 Isolate the MAYTAG Whole Home
Water Filtration System by closing the inlet and
outlet valves. The entire house without water
during this time.
Step 2 Drain the System using the controller.
See section 5.4.7.3 for the base controller and
section 5.4.8.3 for the advanced controller
Step 3 Wearing protective gloves, remove the
System Cap, using the Cap Wrench. Turn the
wrench in a counter-clockwise direction to loosen
it. (Use pressure gauges to ensure no System
pressure first.)
Step 4 Wipe out the inside of the cap with a
clean, soft cloth and place on a clean surface.
Step 5 - Inspect the o-ring on the System for
damage or wear and wipe debris from the o-ring
using a clean, soft cloth.
Step 6 If a replacement o-ring is necessary see
section 6.3.2.2 for o-ring replacement. If a
replacement o-ring is not necessary, re-grease the
o-ring if required.