6-14
6.3.2.3 Installing External Prefilter Replacement
Step 1 - Close the inlet and outlet ball valve.
Turn off the household water. If a bypass valve is
installed, the bypass valve must remain closed.
Step 2 Release the pressure in the System by
using the controller to drain for 1 minute. Refer to
procedure 5.4.7.3 for use of the Base Controller and
procedure 5.4.8.3 for use of the Advanced
Controller.
Step 3 Drain the prefilter by removing the valve
plug.
Step 4 Secure a ¼” hose to the quick connect
fitting and direct the hose into a bucket.
Step 5 Open the drain valve to drain the prefilter
completely into the bucket.
Step 6 For more rapid draining, press on the red
button located on the top of the external prefilter
housing.
Drain Valve
Advanced
Controller
Base Controller
Bypass
Valve
Inlet
Valve
Outlet Valve
Inlet
Valve
Outlet Valve
Page view 104