Troubleshooting Procedures
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven before servicing, unless
testing requires power.
12 16025927
©2005 Maytag Services
Oven Sensor and Meat Probe Charts
OVEN SENSOR
Sensor Type: RTD 1000 platinum
Calibration: 1654 (350° F/177° C)
Temperature F (C) Resistance (Ohms)
100 (38) 1143
200 (94) 1350
300 (149) 1553
350 (177) 1654
400 (204) 1753
500 (260) 1949
600 (316) 2142
700 (371) 2331
800 (427) 2516
900 (483) 2697
1000 (538) 2874
MEAT PROBE
Type: NTC Thermistor
Calibration: 9938 (150° F/65.5° C)
Temperature F (C) Resistance (Ohms)
122 (50) 18963
150 (65.5) 9938
156.2 (69) 8846
165.2 (74) 7456
210.1 (98.9) 3886