©2005 Maytag Services 16025927 A – 15
Installation Instructions (Models JES9750A**, JES9800A**, JES9860A**)
NOTE:
The mounting br ackets shown in figure
16 are as assembled at the factory for floor or
rear wall venting.
a. Right side venting (figure 17).
1. Remove nuts from studs 1, 2 and 3 on the
motor side.
2. Remove bracket and reattach with studs 1 and
2 inserted in holes A and C and replace 3 nuts.
3. Remove nuts from studs 5, 6 and 7 on air inlet
side.
4. Remove bracket and reattach with studs 5 and
6 inserted in holes D and B and replace 3 nuts.
b. Left side venting (figure 17).
1. Remove nuts from studs 1, 2, 3 and 4 on motor
side.
2. Remove bracket.
3. Rotate motor and cover assembly 180 degrees.
4. Reattach bracket with studs 4 and 1 inserted in
holes A and C and replace all 4 nuts.
5. Remove nuts from studs 5, 6, 7 and 8 on inlet
side.
6. Remove bracket and reattach with studs 8 and
5 inserted in holes D and B and replace all 4
nuts.
5. Attach the blower housing to the floor with the outlet
towards the direction of the venting and the inlet
towards the front of the cabinets. In addition, for left
side venting, a spacer of approximately 1-1/2 thick x
9 long (3.81 cm x 22.86 cm) is required under the
mounting bracket flanges of the blower assembly (see
figure 17).
6. Remove the inside wire and outside string from the
first 1-1/2 (3.81 cm) of one end of the 5 (12.7 cm)
flex duct (P/N 702935). Stretch this end of the flex
duct over the end of the 5 x 3-1/4 x 10 (12.7 cm x
25.4 cm) transition and secure with hose clamp (P/N
702331).
7. When the range is placed in position, feed the open
end of the 5 (12.7 cm) flex duct through the hole in
the cabinet side wall and attach to the outlet of the
blower housing with hose clamp (P/N 702331). The
transition should then be attached to the 3-1/4 x 10
(12.7 cm x 25.4 cm) ducting in the cabinet toe space
through the cabinet floor cutout.
Figure 15
Right Cabinet (Top View)
Figure 16
Blower Assembly
Figure 17
View from Air Inlet Side of Blower
3. Make cutout in the cabinet floor of either the ri
g
ht or
left side cabinet as shown in figures 14 or 15.
4. Relocate the mounting brackets on the blower
housing as shown in figure 17.
Figure 14
Left Cabinet (T op View)