Maytag 1800 W - 2005 Specifications Page 21

  • Download
  • Add to my manuals
  • Print
  • Page
    / 55
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 20
©2005 Maytag Services 16025927 21
To avoid risk of electrical shock, personal injury or
death; disconnect power to unit before servicing.
Disassembly Procedures
Transformer
1. Remove power from unit.
2. Remove back panel, see "Back Panel" procedure.
3. Label and disconnect wire terminals from cooling fan.
4. Remove screws securing fan to range chassis.
5. Reverse procedure to reinstall cooling fan.
Bake Element
1. Remove power from unit.
2. Open oven door and remove rack(s).
3. Remove screws securing bake element to rear of
cavity wall.
4. Pull element forward to allow disconnection of
terminals on each element leg.
5. Reverse procedure to reinstall bake element.
Broil Element
1. Remove power from unit.
2. Remove screws securing broil element to top and
rear of oven cavity.
3. Pull broil element forward to allow disconnection of
terminals on each element leg.
4. Reverse procedure to reinstall broil element.
Downdraft Blower Motor (Select Models)
1. Remove power from unit.
2. Remove bottom access panel, see "Bottom Access
Panel" procedure.
3. Disconnect ducting allow for downdraft blower motor
removal.
4. Label and disconnect electrical connections.
5. Remove screws securing motor assembly.
6. Reverse procedure to reinstall downdraft blower
motor (select models).
Downdraft
blower motor
assembly
Bottom Access Panel
1. Grasp top of bottom access panel and gently pull
down and out.
2. Reverse procedure to reinstall bottom access panel.
Indicator Lights
1. Remove control panel, see "Control Panel" procedure
for removal.
2. Label and disconnect wires from indicator light.
3. Squeeze the two tabs on the indicator light body and
gently pull to release from control panel.
4. Reverse procedure to reinstall indicator light.
Oven Sensor
Meat
Probe
Broil Element
Bake
Element
Cooling
Fan
Transformer
Meat Probe Receptacle (Select Models)
1. Turn power off.
2. Remove range from installation position, see
“Removing and Replacing Range” procedure.
3. Remove main top, see "Main Top" procedure for
removal.
4. Remove nut securing meat probe receptacle to cavity.
5. Reverse procedure to reinstall meat probe receptacle.
Back Panel
1. Remove power from unit.
2. Remove range from installation position, see
“Removing and Replacing Range” procedure.
3. Remove screws securing upper back panel to unit.
4. Remove screws securing outside edges of the back
panel to unit chassis.
5. Reverse procedure to reinstall back panel.
Cooling Fan
1. Remove power from unit.
2. Remove back panel, see "Back Panel" procedure.
3. Label and disconnect wire terminals from cooling fan.
4. Remove screws securing fan to range chassis.
5. Reverse procedure to reinstall cooling fan.
Page view 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 54 55