Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless
testing requires power.
©2005 Maytag Services 16025927 13
Component Testing Procedures
Illustration Component Test Procedure Results
Oven light housing
All models
Disconnect connector and test
resistance of terminals ...........................
Measure voltage at oven light ................
Verify bulb is plugged in properly.
Indicates continuity with bulb installed.
12 VAC, see wiring diagram for terminal
identification.
If no voltage is present at oven light,
check wiring or light switches.
Primary
Primary
Secondary
Secondary
Step-down
transformer
All models
Measure voltage at:
Primary terminals ...............................
Secondary terminals...........................
120 VAC (tolerance: 108 to 127 VAC)
10W load (bulb): 11.4 to 11.8 VAC
20W load (bulb): 10.8 to 11.4 VAC
Door plunger switch
All models
Remove switch from unit and measure
the following points:
COM to NO.........................................
Plunger in continuity, plunger out infinity.
Autolatch assembly
All models
Disconnect wires and test for
continuity per wiring diagram.
Refer to Parts Manual for correct
autolatch switch associated with the
correct manufacturing number.
See wiring diagram for schematic layout.
Access assembly by removing two
screws from the front and lowering
control panel.
Common is in neutral position unless
locking or unlocking autolatch assembly.
Halogen element
1200 W,
6.5 in.(165 mm)
Models JES9750A**,
JES9860A**
Disconnect wiring to element and
measure cold resistance of terminals.....
Measure voltage at element...................
Approx. 48
240 VAC
Halogen element
1200 W,
8 in. (200 mm)
Models JES9750A**,
JES9860A**
Disconnect wiring to element and
measure cold resistance of terminals.....
Measure voltage at element...................
Approx. 48
240 VAC
Coil element,
1250 W
4-turn
Models JES9750A**,
JES9860A**
Disconnect wiring to element and
measure cold resistance of terminals.....
Measure voltage at element...................
Approx. 42.5 to 46.9
240 VAC
Coil element,
2100 W
5-turn
Models JES9750A**,
JES9860A**
Disconnect wiring to element and
measure cold resistance of terminals.....
Measure voltage at element...................
Approx. 25.3 to 27.9
240 VAC
Ribbon element
1800 W
Models JES9750A**,
JES9860A**
Disconnect wiring to element and
measure cold resistance of terminals.....
Measure voltage at element...................
Approx. 29 to 32.6
240 VAC
Ribbon element,
1200 W
All models
Disconnect wiring to element and
measure cold resistance of terminals.....
Measure voltage at element...................
Approx. 44.3 to 48.9
240 VAC
Ribbon element,
2200 W (1500 W
inner, 700 W outer)
Model JES9800A**
Disconnect wiring to element and
measure cold resistance of terminals.....
Measure voltage at element...................
Inner: approx. 76 to 84
Outer: approx. 36.7 to 40.5
240 VAC