Maytag 1800 W - 2005 Specifications Page 17

  • Download
  • Add to my manuals
  • Print
  • Page
    / 55
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 16
Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless
testing requires power.
©2005 Maytag Services 16025927 17
Relay Logic
NOTE: Subsequent changes implemented after the release of this technical sheet may have altered the parameters
identified in this chart.
COOKING MODE
BAKE
BROIL
CONVECT FAN HI SPEED
CONVECT FAN LO SPEED
OVEN LIGHT
IDLE
BAKE PREHEAT
BAKE
HIGH BROIL PREHEAT
O
HIGH BROIL
O
LOW BROIL PREHEAT
LOW BROIL
CLEAN PREHEAT
O
CLEAN O
KEEP WARM PREHEAT
KEEP WARM
CONVECT ROAST PREHEAT
O*
CONVECT ROAST
O*
CONVECT BAKE QUICK PREHEAT
O*
CONVECT BAKE PREHEAT
O*
CONVECT BAKE
O*
QUICK PROOFING PREHEAT
O*
QUICK PROOFING
O*
STANDARD PROOFING PREHEAT
STANDARD PROOFING
DRYING PREHEAT
O*
DRYING
O*
INDEX
- OFF
O - ON
- CYCLING
- ON OR OFF (DETERMINED BY USER INPUT)
*Convection fan stops when oven door is opened.
Page view 16