Service Specifications
February 2006 16026956
© 2006 Maytag Services
7
!
WARNING
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
Service Test 6 – Open Damper Test
When selected this test will indicate the current position “O” / “C” (OPEN / CLOSED) of the refrigerator damper. The
Refrigerator Up
key will toggle the damper open and closed. You must allow 1 minute for each attempt to
change the damper position. You should observe proper damper function.
6
Freezer Refri
g
erator
O
6
Freezer Refri
g
erato
r
C
OBSERVE DAMPER FUNCTION
CAUTION
!
Adjustments of Service Test 7 or Service Test 8 will alter the performance of the unit.
Service Test 7 – FF Performance Adjustment
This test will allow adjustment of the control performance points. Each step will incrementally change the
Refrigerator performance warmer (towards 1) or colder (towards 9) as adjusted. The default value is 5.
The refrigerator
/
Up/Down keys are used to adjust the Performance Offset value.
WARMER Í(1 2 3 4 (5) 6 7 8 9) Î COLDER.
7
Freezer Refri
g
erator
5
DEFAULT
7
Freezer Refri
g
erator
6
COLDER
The last FF Performance Offset value displayed before leaving test 7 will be saved when the refrigerator door(s) is
closed.
Service Test 8 – FZ Performance Adjustment
This test will allow the adjustment of the control performance points. Each step will incrementally change the
Freezer performance warmer (towards 1) or colder (towards 9) as adjusted. The default value is 5.
The refrigerator
/
Up/Down keys are used to adjust the Performance Offset value.
WARMER Í(1 2 3 4 (5) 6 7 8 9) Î COLDER.
8
Freezer Refri
g
erator
5
DEFAULT
8
Freezer Refri
g
erator
4
WARMER
The last FZ Performance Offset value displayed before leaving test 8 will be saved when the refrigerator door(s) is
closed.
.