Component Specifications
16026956 February 2006
© 2006 Maytag Services
2
!
WARNING
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power
before servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before
handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding
and polarization.
.
Component Specifications all parts
115VAC/60HZ unless noted
Compressor run capacitor Volt.....................................................
Capacitance ......................................
220 VAC
15 μfd ± 10%
Compressor BTUH .................................................
Watt ...................................................
Current Lock rotor..............................
Current Full load ................................
Resistance Run windings ..................
Resistance Start windings .................
730 BTUH
60 Hz / 125 watts
19.0 amps± 15%
1.09 amps± 15%
3.33 ohms± 15%
4.28 ohms± 15%
Electric damper control Maximum closing time .......................
Temperature Rating...........................
RPM...................................................
8 seconds
20°F- 110°F
5
Thermistor Temperature
77°F....................................................
36°F ...................................................
0°F......................................................
Resistance
10,000 ohms
29,500 ohms
86,300 ohms
Condenser motor Rotation (facing end opposite shaft)
RPM……………………………………
Watt....................................................
Current...............................................
Clockwise
1120 RPM
3.4 watts±15%@115VAC
0.085 amps± 15%@115VAC
Evaporator fan motor Rotation (facing end opposite shaft)
RPM……………………………………
Watt…………………………………….
Clockwise
2800 RPM
5.9 ±15% watts@115VAC
Overload/Relay Ult. trip amps @ 158°F (70°C)...........
Close temperature ...........................
Open temperature............................
Short time trip (seconds)....................
Short time trip (amps @77°F (25°C)..
2.40 amps± 15%
140°F ±10°
230°F ±5°
17 seconds ±5
12 amps ±2amps
Control board Volt.....................................................
See Control Board section for
diagnostics
120VAC, 60 HZ
Thermostat (Defrost) Volt ....................................................
Watt ...................................................
Current...............................................
Resistance across terminals:
Above 42°F ±5°..................................
Below 12°F ±7° ..................................
120/240 VAC
495 watts
10/5 amps
Open
Closed
Evaporator heater
(19 Cu. Ft)
Volt.....................................................
Wattage..............................................
Resistance .........................................
115 VAC
395 ±5% watts @ 115VAC
29 ±5% ohms
Evaporator heater
(22 Cu. Ft)
Volt.....................................................
Wattage..............................................
Resistance .........................................
115 VAC
435 ±5% watts @ 115VAC
29 ±5% ohms
Evaporator heater
(20, 25 Cu. Ft)
Volt.....................................................
Wattage..............................................
Resistance .........................................
115 VAC
470 ±5% watts @ 115VAC
29 ±5% ohms
Light switch Type……………………………………..
Volt………………………………………
Current…………………………………..
SPST NC
125/250 VAC
8 / 6 amps
Water valve, dual (if equipped) Volt.....................................................
Watt....................................................
120 VAC
35 watts (Brown coil)
20 watts (Yellow coil)
Light switch / Interlock Type……………………………………..
Volt………………………………………
Current…………………………………..
SPDT NO/NC
125/250 VAC
5 / 2.5 amps
Page view 1