Maytag MSD2357HEB Specifications

Browse online or download Specifications for Fridges Maytag MSD2357HEB. Maytag MSD2357HEB Specifications User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 4
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Service Specifications Side-by-Side RefrigeratorTechnical Information
ASD2626HEB ASD2626HEB0, ASD2626HEQ ASD2626HEQ0,
ASD2626HES ASD2626HES0, ASD2626HEW ASD2626HEW0,
ASD2628HEB ASD2628HEB0, ASD2628HEQ ASD2628HEQ0,
ASD2628HES ASD2628HES0, ASD2628HEW ASD2628HEW0
!
WARNING
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
Due to a possibility of personal injury or property damage, always contact an authorized technician for
service or repair of this refrigerator.
3. Release the refrigerator door light switch.
4. The control will display Fd to confirm entry into the Forced Defrost Mode.
Freeze
r
Refri
g
erator
CAUTION
!
F
All safety information must be followed as provided in Service Manual 16022689.
5. Entry is confirmed by pressing the Refrigerator Down
key once more. The unit is off and in the Defrost Mode.
Note: All control functions will be turned off (Compressor, Defrost, Evaporator Fan, the damper will
remain in its current position)
!
WARNING
6. The control will default to the short run period test as shown here
Freeze
r
Refri
g
erato
r
S
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless testing is required. Discharge capacitors through a 10,000 ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
Note: You can toggle between the (S)hort and (L)ong test mode by pressing the Refrigerator UP
Key.
Long Test mode is used for factory test and should not be used in the field.
Freezer Refri
g
erator
No-Load Performance, Controls in Normal Position
Kw/24 hr ±0.4
Percent Run Time
±10%
Cycles/24 hr
±25%
Refrigerator Center
Compartment
Average Food
Temperature ±3°F
Freezer Compartment
Average Food
Temperature ±3°F
Ambient °F 70° 90° 110° 70° 90° 110° 70° 90° 110° 70° 90° 110° 70° 90° 110°
26 cu ft 1.2 1.85 2.6 35 55 75 24 24 19 37 39 42 0 0 -2
L
7. Once the desired mode is displayed, confirm the forced defrost by pressing the Refrigerator
down Key once.
The defrost will begin immediately and the display will return to a normal operating display with set point values.
Freeze
r
Refri
g
erator
4
4
Temperature Relationship Test Chart
Evaporator
Outlet
±3°F
Evaporator
Inlet
±3°F
Suction Line
±7°F
Average Total
Wattage ±10%
Suction
Pressure
±2 PSIG
Head Pressure
± 5 PSIG
Ambient °F 70° 90° 70° 90° 70° 90° 70° 90° 70° 90° 70° 90°
26 cu ft -15 -15 -16 -16 72 98 132 138 6"(Vac.) 0 87 137
8. Close the Refrigerator door(s). You are in the defrost mode
Note: Forced Defrost mode can be exited at any time prior to step 7 by closing the Refrigerator Door(s).
Service Test Mode:
The service test functions are performed using the refrigerator display and keypad. Enter the Service Test Mode
by performing the following sequence of events
1. Hold the refrigerator door light switch closed.
Schematic
2. Press the Refrigerator Temperature Up
keypad 3 times consecutively.
Note: The 3 Keystrokes must be done consecutively and within 10 seconds.
3. Release the refrigerator door light switch.
4. The control will display SE to confirm entry into the service mode.
Freeze
r
Refri
erator
S
E
5. Entry to the Service Menu is confirmed by pressing the Refrigerator Up
key once more.
6. The control will display its software version for 3 seconds.
Freezer Ref
2
ri
g
erato
r
5
7. Following the software revision display the freezer display will read the first test number in the
diagnostic tree. The refrigerator display will be blank
Freeze
r
Re
1
fri
g
erator
Note: All control functions will be turned off (Compressor, Defrost, Evaporator Fan, the damper will
remain in its current position)
8. You are now in the SERVICES TEST operational mode and may use the diagnostic tests
The Service Test Mode can be exited at any time by closing the Refrigerator Door(s).
April 2004 4 16023095
April 2004 1 16023095
© 2004 Maytag Services © 2004 Maytag Services
Page view 0
1 2 3 4

Summary of Contents

Page 1 - Schematic

Service Specifications Side-by-Side RefrigeratorTechnical Information ASD2626HEB ASD2626HEB0, ASD2626HEQ ASD2626HEQ0, ASD2626HES ASD2626HES0, ASD2

Page 2 - Forced Defrost Mode:

Component Specifications Service Specifications April 2004 3 Note: The 3 keystrokes must be consecutive and within 10 seconds. !WARNING To avoid ris

Page 3 - DEFROST THERMOSTAT OPEN

Wiring Diagram Service Specifications April 2004 8 16023095 April 2004 5 16023095 © 2004 Maytag Services © 2004 Maytag Services !WARNING

Page 4 - DEFAULT

Service Specifications Service Specifications April 2004 6 16023095 April 2004 7 16023095 © 2004 Maytag Services © 2004 Maytag Services !WA

Comments to this Manuals