Service Test 1 Defrost Thermostat & Defrost Circuit Test
When selected this test will display the state of the defrost thermostat. In order to perform this test the defrost
heater will be energized. The test is activated and deactivated using the Refrigerator Up
key. Once activated,
this test must be deactivated to move to another test number. The Freezer Up
/ Down
keys allow
selection of the test to be performed.
This test also allows observation and measurement of proper defrost function. You can observe defrost heat and
voltages while the test is activated.
1
Freezer Refri
g
erator
O
DEFROST THERMOSTAT OPEN
1
Freezer Refri
g
erato
r
S
DEFROST THERMOSTAT SHORTED (CLOSED)
Service Test 2 – Compressor/Condenser Fan Test
When selected and activated this test will operate the Compressor/Condenser Fan circuit. You should evaluate
proper operation of the compressor and condenser fan. The Refrigerator Up
key will toggle between “O” / “F”
(ON & OFF) the compressor drive circuit. The test must be “deactivated” or in the OFF position to move to another
test selection.
2
Freezer Refri
g
erator
O
2
Freezer Refri
g
erator
F
OBSERVE COMPRESSOR & CONDENSER FAN FUNCTION
Service Test 3 – Evaporator/Freezer Fan Test
When selected and activated this test will operate the freezer fan. The Refrigerator Up
key will toggle
between “O” / “F” (ON & OFF) the fan drive circuit. You will have to inspect the fan for proper function. The test
must be “deactivated” or in the OFF position to move to another test selection.
3
Freeze
r
Refri
g
erato
r
O
3
Freezer Refri
g
erato
r
F
OBSERVE FAN OPERATION