2
Printed in U.S.A.. • Impreso en los Estados Unidos • Stampato negli Stati Uniti (revised 06/23/04) 22001460
Proper installation is the responsibility of the owner.
HOWEVER, SERVICE CALLS PERFORMED AS A RESULT OF POOR SET-UP, ADJUSTMENT
AND CONNECTION ARE THE RESPONSIBILITY OF THE INSTALLER.
Make sure you have everything necessary for proper installation.
1. GROUNDED ELECTRICAL OUTLET is required. See Electric Requirements.
2. POWER CORD for electric dryers (except Canada).
3. EXHAUST SYSTEM – must be rigid metal or flexible stiff walled metal exhaust ducting. See
Exhaust Requirements.
CABINET DIMENSIONS
(Depth with dryer door open 90
o -
38.25” / 97 cm)
• Cutting knife
• Nut drivers
• Level
• Duct tape
• Crescent wrench
Tools needed for installation
Note:
The height of the dryer from top to floor is 33 1\4" this includes the leveling leg screwed all the way in. The customer can
unscrew the leg out an additional 7\8" for a total overall height of 34 1\8".
DRYER DIMENSIONS INCH (CM)
A. Height – Overall* 33.25” (84.5)
B. Depth to Front of Control Dial 23.75” (60)
C. Width 23.5” (59.7)
D. Depth – With Dryer Door Open 90° 40” (101.6)