The water and ice dispenser will not operate properly
• Refrigerator connected to a water supply and the supply
shutoff valve turned on? Connect refrigerator to water
supply and turn water shutoff valve fully open.
• Kink in the water source line? Straighten the water source
line.
• New installation? Flush and fill the water system. See "Water
and Ice Dispensers."
• Is the water pressure at least 35 psi (241 kPa)? The water
pressure to the home determines the flow from the dispenser.
See "Water Supply Requirements."
• Water filter installed on the refrigerator? Remove filter and
operate dispenser. If water flow increases, the filter may be
clogged or incorrectly installed. Replace filter or reinstall it
correctly.
• Refrigerator door closed completely? Close the door
firmly. If it does not close completely, see "The doors will not
close completely."
• Recently removed the doors? Make sure the water
dispenser wire/tube assembly has been properly reconnected
at the top of the refrigerator door. See "Refrigerator Doors
and Drawer."
• Reverse osmosis water filtration system connected to
your cold water supply? This can decrease water pressure.
See "Water Supply Requirements."
Water is leaking from the dispenser system
NOTE: One or two drops of water after dispensing is normal.
• Glass not being held under the dispenser long enough?
Hold the glass under the dispenser 2 to 3 seconds after
releasing the dispenser lever.
• New installation? Flush the water system. See "Water and
Ice Dispensers."
• Recently changed water filter? Flush the water system. See
"Water and Ice Dispensers."
Water from the dispenser is warm
NOTE: Water from the dispenser is only chilled to 50°F (10°C).
• New installation? Allow 24 hours after installation for the
water supply to cool completely.
• Recently dispensed large amount of water? Allow
24 hours for water supply to cool completely.
• Water not been recently dispensed? The first glass of water
may not be cool. Discard the first glass of water.
• Refrigerator connected to a cold water pipe? Make sure
the refrigerator is connected to a cold water pipe. See "Water
Supply Requirements."
WATER FILTER CERTIFICATIONS
State of Calitbrnia
Department of Public llea[th
Water TreatmentDevice
Certificate Number
03- 1583
Datelssued: September 16, 2008
Date Revised: April 22, 2009
Trademark/Model Designation
UKF8001 AXX-750
469006-750
67003523"750
Manufacturer: Cun0
The water treatment,
Replacement Elements
Cysts
Turbidity
Organic Contamlnhhts
Atrazine
l.,d no
Carbofuran
p-dichlorobenzene
Toxaphcne
Tetrachloroethylene
Rated Service Capacity: 750 gal. Rated Service Flow: 0.78 gpm
Conditions of Certification:
Do not use where water is microbiologically unsali_ or with water of unknown quality, except _hat systems certified
{br cyst reduction may be used on disinl_cted waters that may contain Iilterable cysts.
State of Calitbrnia
Department of Public Ilealth
Water Treatment Device
Certificate Number
09- 1979
Date Issued: May 8, 2009
Trademark/Model Designation Reolacement Elements
UKF8001AXX-701 t_KF8001
; 2
Manutacturer: Cuno lm a 3MComtlany
Turbidity
Organic Contaminants
Alrazine
Benzene
Carbofm-an
Chlorobenzene
Endrin
Ethylbcnze_c
l,indane
o-dichlorobenzenc
p-dichloroben×enc
Telrachloroethy]enc
Toxaphene
Rated Service Capacity: 200 gal Rated Service Flow: a ¢_ gpm
Conditions of Certification:
Do not use where water is microbiologically unsali_ or with water of unknown quality, excep/that systems certified
lbr cyst reduction may be used on disinli:cted waters thai may contain liherable cysts.
17
Comments to this Manuals