Component Testing
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
©2005 Maytag Services 16025860
9
Component Description Test Procedures
Evaporator The low pressure in the evaporator
allows liquid refrigerant exiting the
capillary to expand into a gas.
Expansion cools evaporator coil
temperature to approximately -20°F
transferring heat from freezer section to
refrigerant.
Passing through suction line back to the
compressor, the refrigerant picks up
superheat (a relationship between
pressure and temperature that assures
complete vaporization of liquid
refrigerant) as the result of capillary tube
soldered to suction line.
Refrigerant gas is circulated through the
suction line by compressor, completing
refrigeration cycle.
Test for leaks in evaporator with electronic leak detector or with soap solution.
Compressor oil is circulated with refrigerant; check for the presence of oil when
checking for leaks.
For minute leaks
1. Separate evaporator from rest of refrigeration system and pressurize
evaporator up to a maximum of 140 PSI with a refrigerant and dry nitrogen
combination.
2. Recheck for leaks.
Evaporator heater
(defrost)
Activated when defrost thermostat,
defrost timer, and freezer control
complete circuit through heater.
Check resistance across heater.
To check defrost system :
1. Thermocouple defrost thermostat and plug refrigerator into wattmeter.
2. Turn into defrost mode. Wattmeter should read specified watts (according to
Technical Data Sheet).
3. When defrost thermostat reaches specified temperature ±5°F (see Technical
Data Sheet), thermostat should interrupt power to heater.
Thermostat
(defrost)
Thermostat is in a series circuit with
terminal 2 of defrost timer, and defrost
heater.
Controls the circuit from freezer
thermostat through defrost terminator to
defrost heater. Opens and breaks circuit
when thermostat senses preset high
temperature.
Test continuity across terminals.
With power off and evaporator coil below freezing, thermostat should show
continuity when checked with ohmmeter. See “Heater, evaporator (defrost)”
section for additional tests.
After defrost thermostat opens, thermostat remains open until end of defrost timer
cycles and refrigerator starts cooling again. Defrost thermostat senses a preset
low temperature and resets (closes).
WARNING
!
To avoid severe personal injury or death from sudden erruption of
high pressurres gases, observe the following:
Protect against a sudden eruption if high pressures are required
for leak checking.
Do not use high pressure compressed gases in refrigeration
systems without a reliable pressure regulator and pressure relief
valve in the lines.