PRODUCT MODEL NUMBER
PRODUCT DIMENSIONS
VENTING DESIGN SPECIFICATIONS
Electrical: A 120-Volt, 60-Hz, AC-only, 15- or 20-amp electrical supply with
a fuse or circuit breaker. A time-delay fuse or time-delay circuit breaker is
recommended. It is recommended that a separate circuit serving only this
microwave oven be provided.
Microwave Hood Combination
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10609724A
12/17/14
CABINET OPENING DIMENSIONS
12" (30.5 cm) min.
14" (35.6 cm) max.
min.
A. 2" x 4" wall stud
B. Grounded 3-prong outlet
66" (167.6 cm) min.
The grounded 3-prong outlet must be inside the upper cabinet.
*30" (76.2 cm) is typical for 66" (167.6 cm) installation height.
Exact dimensions may vary depending on type of range/cooktop below.
MMV1174D
This section is intended for architectural designer and builder/contractor
reference only.
NOTES:
●
Vent materials needed for installation are not provided with microwave hood
combination.
●
We do not recommend using a flexible metal vent.
●
To avoid possible product damage, be sure to vent air outside, unless using
recirculation installation. Do not vent exhaust air into concealed spaces, such
as spaces within walls or ceilings, attics, crawl spaces or garages.
For optimal venting installation, we recommend:
●
using roof or wall caps that have back draft dampers
●
using a rigid metal vent
●
using the most direct route by minimizing the length of the vent and number of
elbows to provide efficient performance
●
using uniformly sized vents
●
using duct tape to seal all joints in the vent system
●
using caulking compound to seal exterior wall or roof opening around cap
●
not installing 2 elbows together, for optimal hood performance
If venting through the wall, be sure that there is proper clearance within the wall
for the damper to open fully.
If venting through the roof, and rectangular to round transition is used, be sure
there is at least 3" (7.6 cm) of clearance between the top of the microwave oven
and the transition piece.
Comments to this Manuals