Service Specifications
January 2005 16025987
© 2005 Maytag Services
3
!
WARNING
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
Programming Mode:
NOTE: The Program Code is located on the Serial Plate on this unit after the word Code.
1. Open the Fresh Food door and press and hold the Door Alarm Keypad
Door
A
larm
.
2. Press and hold Freezer Temperature Down Keypad
.
3. Release the Door Alarm Keypad
Door
A
larm
and wait 3 seconds.
4. The control will display PE to indicate the programming mode.
Fast
Ice
Reset
Filter
Vacation
Mode
Tem p
Alert
Door
Alarm
Max
Cool
Freezer
Refrigerator
Order Replace
5. Entry is confirmed by pressing the Freezer Temperature Down Keypad
once more.
6. The control will display the current Program CODE. This value should be validated with the Program CODE
printed on the unit serial plate.
PE0
Fast
Ice
Reset
Filter
Vacation
Mode
Temp
Alert
Door
Alarm
Max
Cool
Freezer
Refrigerator
Order Replace
000
NOTE: If the Program CODE is correct, the Programming Mode is exited by closing the Refrigerator door(s).
7. Press the Refrigerator Temperature UP Keypad
or Refrigerator Down Keypad
to change the digit
value with each key press.
8. The decimal point indicates the selected digit. Press the Freezer Temperature UP Keypad
to select the
next digit.
9. Once the desired Program CODE is entered, press and hold the Freezer Temperature DOWN Keypad
until the Program CODE begins flashing indicating it has been saved.
NOTE: If you attempt to enter an invalid Program CODE the control will not save the new code, but will beep. (The
unit will NOT run with a Program CODE of 0000).Once the Program CODE has been saved the
Programming Mode is exited by closing the Refrigerator door(s). If the new code is incorrect this process
should be repeated after closing the Refrigerator door(s).
The Programming mode can be exited at any time by closing the Refrigerator Door(s) or will exit if
unattended for four minutes.
Defrost Operation:
The Control Board adapts the compressor run time between defrosts to achieve optimum defrost intervals by
monitoring the length of time the defrost heater is on. After initial power up, defrost interval is 4 hours
compressor run time. Defrost occurs immediately after the 4 hours.
Page view 2
1 2 3 4 5 6 7 8

Comments to this Manuals

No comments