2_0 EdwardsStreet SE
Cieveiand.Tennessee87311
Tel:422-472-3333
Fax:_22-4786710
DIRECT EXHAUST
An exhaust hood positioned to line up with the dryer exhaust pipe can be installed directly
through an outside wall. This would be the shortest and most direct exhaust method.
To exhaust up, route standard 4" diameter ducting up the recess and in the cabinet back using
the furnished retaining strap an screws to get nearly flush to wall installation. To exhaust to
the side or down, install the furnished 4" long duct with four "S" clips to the inner dryer
exhaust, then use standard 4" ducting. This will position the dryer about 4 1/2" away from
the wall. Flush to wall side exhausting may be done by going above the dryer before going
sideways.
When exhausting down, wallboard can be removed from the wall to get the dryer closer to
the wall by placing the exhaust pipe between the studs. Check local codes for required
exhaust clearances.
Install ductwork from the dryer to exhaust hood. All joints must be made so exhaust end of
one pipe is inside the intake end of the next pipe. On flexible metal ductwork, all joints
should be secured with a 304630 clamp. DO NOT use sheet metal screws when assembling
rigid ducting. Joints should taped.
Ill
FLEXIBLE DUCTWORK LIMITATIONS
Flexible metal ductwork should not exceed 34' of straight 4" ducting. The exhaust hood is
equivalent to 8' of duct and each 90 degree bend is equivalent to 8'. As an example if an
exhaust hood is used and two 90 degree bends, the maximum straight run would be 10'.
NOTE: If the radius of a bend with 4" duct is 12" or greater, the bend can be considered a
straight run. No more than three 90 degree bends should be used in any run with an exhaust
hood.
If flexible metal exhaust ducting is used, cut a short piece (about 3") off the male end of a 4"
diameter metal duct pipe. The short extension can be secured to the dryer exhaust with the
clips and the flexible metal duct can be clamped to the short extension.