Ice ‘N Water Systems
38 16025628 ©2005 Maytag Services
Symptom Possible
Cause
Test Procedure Repair
Failed Main
dispenser
switch (failed
open)
Disconnect power. Remove both leads from the
switch and measure resistance across switch
terminals. Resistance should read less than 1
in
this position and higher than 10 M when switch
is open.
Replace switch.
No continuity
Disconnect power. Remove the cover of freezer
door hinge located on top of the unit and
disconnect the connectors. Check OR wire (pin 4
of 10-pin connector) for continuity.
Repair open
connection.
Cubed LED is illuminated
but does not dispense
cubed ice when Main
dispenser switch is
pressed.
Failed auger
motor or PCB.
With PCB powered, press the Main dispenser
switch. Measure voltage on pin 4 (OR wire) of 10-
pin connector. Voltage should read 120VAC.
Replace auger motor if
voltage reads 120VAC.
If not, replace PCB.
Failed Main
dispenser
switch (failed
short)
Disconnect power. Remove both leads from the
switch and measure resistance across switch
terminals. Resistance should read higher than 10
M when switch is open and less than 1 when
switch is closed.
Replace switch Cubed ice starts to
dispense as soon as
Cubed mode is selected
without pressing the Main
dispenser switch
Failed PCB
With PCB powered, measure voltage on pin 4
(OR wire) of 10-pin connector. Voltage should
read 0 VAC.
Replace PCB.
Dispenser operates
continuously even when
Dispenser Lock mode is
activated.
Failed PCB With PCB powered, measure voltage on pin 5 (BK
wire) of 10-pin connector. Voltage should read 0
VAC.
Replace PCB
Auto Light mode does not
operate.
Failed PCB With PCB powered and Auto Light activated,
cover the light sensor. Measure voltage on pin 2
(BR wire) of 10-pin connector. Voltage should
read 1/2 the AC power supply (120 VAC).
Replace PCB.
Ice or Water dispenser
mechanism runs
continuously.
Failed PCB With PCB powered, measure voltage on pin 5 (BK
wire) of 10-pin connector. Voltage should read 0
VAC.
Replace PCB.
Filter Status LED never
changes to red.
Failed PCB Verify with the user if unit has been unplugged for
a long period.
Demonstrate reset operation to customer.
Replace water filter and
reset Filter Status.
Replace PCB if problem
continues. Customer
education.
Failed solenoid Disconnect power. Remove both leads from the
solenoid and measure the resistance across
solenoid terminals. Resistance should read
101.2 ± 10%.
Replace solenoid.
1. Auger motor operates in
Cubed or Crushed mode
but ice door chute never
opens.
2. Auger motor operates in
Cubed or Crushed mode
but ice door chute never
closes.
Failed PCB Measure voltage on pin 1 (GY wire) of 10-pin
connector. Voltage should read approximately
55VDC when ice chute door is open (solenoid
energized) or 0VDC when closed (solenoid not
energized).
Replace PCB.
No LED lit, Water
dispenser operates, auger
motor operates only in
Cubed mode and ice chute
door does not open or
remains open.
Failed PCB
Replace PCB
No LED lit, Water
dispenser operates, auger
motor operates only in
Cubed mode and dispenser
light is on continuously.
Failed PCB
Replace PCB
Neither Water, Crushed or
Cubed LED will not
illuminate but Water,
Crushed or Cubed mode
operates properly when
selected.
Failed PCB Replace PCB