Maytag MET3800XW Installation Guide Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
16
1. Prepare to connect neutral
ground wire and neutral wire
B
E
A
Remove center terminal block screw (B). Remove neutral
ground wire (E) from external ground conductor screw (A).
C
E
B
Connect neutral ground wire
and neutral wire
2.
Connect neutral ground wire (E) and neutral wire (white or
center wire) (C) of power supply cord or cable under center
terminal block screw (B). Tighten screw.
Connect remaining wires
3.
Place hooked ends of remaining wires under outer terminal
block screws (hooks facing right). Tighten screws.
A
G
Connect external ground wire
4.
Connect a separate copper ground wire (G) from the external
ground conductor screw (A) to an adequate ground. Finally,
reinsert tab of terminal block cover into slot of dryer rear
panel. Secure cover with hold-down screw. Now, go to
“Venting Requirements.”
Optional 3-Wire Connection
IMPORTANT: You must verify with a qualied electrician that
this grounding method is acceptable before connecting.
Connect remaining wires
4.
Place hooked ends of remaining direct wire cable wires
under outer terminal block screws (hooks facing right).
Squeeze hooked ends together and tighten screws. Finally,
reinsert tab of terminal block cover into slot of dryer rear
panel. Secure cover with hold-down screw. Now, go to
“Venting Requirements.”
B
C
Place hooked end of neutral wire (white or
center) (C) of direct wire cable under center
terminal block screw (B). Squeeze hooked
end together. Tighten screw.
3. Connect neutral wire