Disassembly Procedures
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
32 16025629 ©2005 Maytag Services
Light Bulb Sockets
1. After following procedure on removing light bulb
assembly.
2. Disconnect wires to sockets.
3. Squeeze tab on back side of socket to release it from
assembly.
4. Reverse procedure to reassemble.
Defrost Timer (some models)
1. After following procedure on removing light bulb
assembly.
2. Remove hex head screws holding timer to assembly.
3. Disconnect plug from timer.
4. Reverse procedure to reassemble.
DEFROST TIME
R
Mechanical Control Model
PC Control Board (some models)
1. Remove light shield by sliding shield to rear to release
cover.
2. Depress with a screw driver through two slots in the
front of the light housing release tabs to release
Control Board housing.
3. Control Board housing will drop down exposing
Control Board.
4. Unplug two wire harnesses plugged into the Control
Board.
5. Release tabs holding Control Board to housing.
CONTROL BOARD
RELEASE TABS
LIGHT COVER
Mid Level Electronic Model
Light Switch
1. After following procedure on removing light bulb
assembly.
2. Disconnect wires from light switch.
3. Squeeze tab to release light switch from light
assembly.
4. Reverse procedure to reassemble.
Temp- Assure
TM
Damper Control (some models)
1. Remove light shield.
2. Remove damper control cover and foam insert by
pulling straight on sides of rear cover and tilt forward
1/2” to 1”. This will release the cover from the tabs
holding it in place.
3. Release tension on damper control belt by
squeezing tabs on bottom of belt tensioner to
release tensioner from it’s holding tabs.
4. Slip belt off of damper control cog.
5. Damper can be removed by pushing in tabs on left
and right side of damper control to release damper
from rear wall.
6. Reverse procedure to reassemble.