Component Testing
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
10 16025629
©2005 Maytag Services
Component Description Test Procedures
Thermistor
Temperature sensing device Check resistance across leads.
Temperature Resistance
77°F 10,000 ohms
36°F 29,500 ohms
0°F 86,300 ohms
Condenser motor
Condenser fan moves cooling air across
condenser coil and compressor body.
Condenser fan motor is in parallel circuit
with compressor.
Check resistance across coil.
ECM condenser
motor
Condenser fan moves cooling air across
condenser coil and compressor body.
Condenser fan motor is in parallel circuit
with compressor.
Check resistance across coil.
Electric damper
control
Damper control balances the air delivery
between refrigerator and freezer
compartments providing temperature
control for refrigerator.
Electrical voltage activates damper
control and door closes restricting flow of
air from freezer compartment to
refrigerator compartment.
Check resistance across terminals.
If no resistance across terminals replace damper control.
Damper control
Damper control balances the air delivery
between refrigerator and freezer
compartments providing temperature
control for refrigerator.
Internal capillary activates damper control
and door closes restricting flow of air
from freezer compartment to refrigerator
compartment.
Subject capillary to appropriate temperature (refer to Technical Data Sheet for
model being serviced).
Damper door should close to within ¼" of completely shut.
If altitude adjustment is required, turn altitude adjustment screw 1/8 turn
clockwise for each 1,000 feet increase in altitude.
There are no electrical connections to damper control. See Technical Data Sheet
for damper specifications for unit being serviced.