International Commercial Microwave–Technical Information
April 2006 16026971
©2006 Maytag Services
1
230 VAC, 50 Hz model
ALD510 P1331005M UALD510 P1331006M
MLD510 P1331009M UMLD510 P1331010M
Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or
repair of this unit.
Refer to Service Manual 16026969 for installation, operating, testing, troubleshooting, and disassembly
instruction.
CAUTION
!
All safety information must be followed as provided in Service Manual 16026969.
!
WARNING
To avoid the risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
Models ALD510
MLD510
UALD510
UMLD510
Power Source
Voltage AC 230 VAC 230 VAC
Amperage (Single Unit) 15 A 15 A
Frequency 50 Hz 50 Hz
Single Phase, 3 wire grounded X X
Plug CEE 7/7 Schuko BS1363A
Power Output Microwave
Nominal microwave energy (IEC705) 1000 Watts 1000 Watts
Minimum temperature rise ( T) 10ºF / 5ºC 10ºF / 5ºC
Operating Frequency 2450 MHz 2450 MHz
Power Consumption
Microwave only 1500 Watts 1500 Watts
Dimensions
Cabinet (in cm)
Width 22" 56 cm 22" 56 cm
Height 13 1/2" 34.4 cm 13 1/2" 34.4 cm
Depth 18 29/32" 47.9 cm 18 29/32" 47.9 cm
Oven Interior (in cm)
Width 14 1/2" 36.9 cm 14 1/2" 36.9 cm
Height 8 3/4" 22.1 cm 8 3/4" 22.1 cm
Depth 15 3/4" 40 cm 15 3/4" 40 cm
Weight
Uncrated 40.7 lbs. 18.5 kg 40.7 lbs. 18.5 kg
Features
Timer 60 minute 60 minute
Power Selection 5 Levels 5 Levels
Cavity Volume 1.2 cu. Ft. 1.2 cu. Ft.
Page view 0
1 2 3 4 5

Summary of Contents

Page 1 - 230 VAC, 50 Hz model

International Commercial Microwave–Technical Information April 2006 16026971 ©2006 Maytag Services 1230 VAC, 50 Hz model ALD510 P1331005M UALD510

Page 2 - Component Testing Procedures

Component Testing Procedures !WARNI NG To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor

Page 3

Component Testing Procedures !WARNI NG To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor

Page 4 - Power Test

Power Test !WARNI NG To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor before servicing,

Page 5 - Wiring Diagram and Schematic

Wiring Diagram and Schematic !WARNI NG To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor