Maytag PPH2RF Service Manual Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
6

H = Heat Pump
F = 15 SEER
Electrical Code
K = 208/230-60-1


x 1000 Btu
P P H 2 R F 024 K A

Round Duct
P = Premier
P = Package
(a) Amperage and wire size based on refrigeration system only with 60° C wire, 50 ft. length. See Electrical Data tables for supplemental electric heaters. Refer to
National Electric Code for additional derating factors for field installed conductors.
(b) Use time delay fuse or "HACR" type circuit breaker.
 X24KA X36KA X48KA X60KA
Capacities
Cooling BTU/h 24,000 34,600 46,500 55,000
SEER 15 15 15 15
EER 12 12 12 12
Heating BTU/h 47° F 23,000 34,600 44,000 56,000
HSPF 8.0 8.0 8.0 8.0
Sound Rating 72 71 70 71

Operating Voltage Range 187 - 253 187 - 253 187 - 253 187 - 253
Min. Circuit Ampacity (a) 19.6 24.1 35.7 45.2
Field Wire Size — AWG (a) 10 10 8 6
Delay Fuse — Max. (b) 30 35 50 70
Total Unit — AMPS 16.7 20.3 30.4 38.0
Compressor
Volts 208 - 230 208 - 230 208 - 230 208 - 230
Rated Load Amps 11.7 15.3 21.2 28.8
Lock Rotor Amps 58.3 83.0 104.0 152.9

Fan Motor — HP - RPM 1/5 - 825 1/4 - 1100 1/2 - 2 speeds 1/2 - 2 speeds
Fan Motor — Amps 1.2 1.2 3.8 3.8
Fan Dia. — CFM 20" - 2800 20” - 3000 20” - 3400 24” - 4000

Blower Motor — HP 1/2 1/2 3/4 3/4
Blower Motor — Amps 3.8 3.8 5.4 5.4
 136 143 189 260
 313 320 398 443
