Maytag HRN31250P User Manual

Browse online or download User Manual for Water boiler Maytag HRN31250P. Maytag HRN31250P User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
1
www.maytagwaterheaters.com
PRINTED IN THE U.S.A. 0505 PART NO. 66001897
184683-001
FOR POTABLE WATER HEATING ONLY
NOT SUITABLE FOR SPACE HEATING
NOT FOR USE IN
MANUFACTURED (MOBILE) HOMES
Model Numbers
For Your Safety
AN ODORANT IS ADDED TO THE GAS USED
BY THIS WATER HEATER.
POWER VENT
GAS WATER HEATER
USER’S GUIDE
Series Twelve
HRN11240P
HRN31240P
HRP11240P
HRP31240P
HRN11250P
HRN31250P
HRP11250P
HRP31250P
HRN11275P
HRN31275P
HRP11275P
HRP31275P
Page view 0
1 2 3 4 5 6 ... 47 48

Summary of Contents

Page 1 - Series Twelve

1www.maytagwaterheaters.comPRINTED IN THE U.S.A. 0505 PART NO. 66001897 184683-001FOR POTABLE WATER HEATING ONLYNOT SUITABLE FOR

Page 2 - IMPORTANT DEFINITIONS

10Facts to Consider About the LocationCarefully choose an indoor location for the new water heater,because the placement is a very important considera

Page 3 - SAFETY PRECAUTIONS

11INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQUIDS(VAPORS) ARE LIKELY TO BE PRESENT OR STORED(GARAGES, STORAGE AND UTILITY AREAS, ETC.):Flammable liquid

Page 4 - TABLE OF CONTENTS

12• 12” minimum from the ground, 9” ceiling overhangs, seeFigure 11. FIGURE 11.• The Power Vent outlet terminal shall terminate

Page 5 - PRODUCT SPECIFICATIONS

13 FIGURE 16.Insulation BlanketsInsulation blankets available to the general public for externaluse on gas water heaters are not necessar

Page 6 - ACCESSORIES AND TOOLS NEEDED

14B. ALL AIR FROM OUTDOORS: (See Figures 18, 19 and 20)The confined space shall be provided with two permanentopenings, one commencing within 12 inche

Page 7 - INSTRUCTIONS FOR INSTALLATION

15Figure 22 shows the typical attachment of the water piping tothe water heater. The water heater is equipped with 3/4” NPTwater connections for 40,0

Page 8 - TYPICAL INSTALLATION

16Secure all insulation using tape.FIGURE 23.Temperature-Pressure Relief ValveThis heater is provided with a properly certified combinationtemperatur

Page 9

17The temperature-pressure relief valve must be manuallyoperated at least once a year. Caution should be taken toensure that (1) no one is in front o

Page 10 - LOCATING THE NEW WATER HEATER

18USE WITHOUT POWER CORDIf power cord cannot be used, then follow these wiringinstructions.• Provide a way to easily shut off the electric power whenw

Page 11 - FIGURE 10

19VentingTo insure proper venting of this gas-fired water heater, thecorrect vent pipe diameter must be utilized. Do not install othergas appliances o

Page 12 - FIGURE 15

2SAFE INSTALLATION, USE AND SERVICEYour safety and the safety of others is extremely important in the installation, use and servicing of this water he

Page 13 - Insulation Blankets

2075 GALLON 70,000 AND 75,000 BTU/HR MODELS ONLY -OPTIONAL 4” VENT PIPING4” PVC, ABS or CPVC Schedule 40 vent piping: • A wire screen to fit a 4” PCV,

Page 14 - Water Piping

21• The water heater requires its own (separate) ventingsystem.• 2” and 3” PVC, ABS or CPVC Schedule 40 piping and fittingsare acceptable materials fo

Page 15 - FIGURE 21

2240 AND 50 GALLON 40,000 BTU/HR MODELSSee Chart below for maximum length. FIGURE 39.• The total vertical and horizontal vent run cannot exceed the

Page 16 - FIGURE 24

2375 GALLON 70,000 AND 75,000 BTU/HR MODELS ONLY3” DIA. VENT NUMBER OFMAX. LENGTH (FT.) 90 ELBOWS*(Inside bldg.)60 155 250 345 440 535 675 GALLON 70,

Page 17 - Filling the Water Heater

24FIGURE 42.The 3” )or optional 2” or 4”) PVC, ABS or CPVC Schedule 40vent pipe can be run from the water heater through the wall orfrom the wall to t

Page 18 - Wiring Diagram

25• 4” and 3” PVC, ABS or CPVC Schedule 40 piping and fittingsare acceptable materials for vent system on all 75 gallon70,000 and 75,000 BTU/HR models

Page 19

26ALL 40 AND 50 GALLON 40,000 BTH/HR MODELS ONLY -OPTIONAL 2” VENT PIPING2” DIA. VENT NUMBER OFMAX. LENGTH (FT.) 90o ELBOWS*50 145 240 335 430 525 6*

Page 20

27• Contaminants in gas lines cancause fire or explosion.• Clean all gas piping beforeinstallation.• Install drip leg in accordancewith NFPA 54.Sedime

Page 21

28OPERATING INSTRUCTIONSThis water heater is equipped with an electronically operatedventing system and electronic control. For the burner to comeon,

Page 22 - FIGURE 41

29Operating Propane gas is heavier than air. Should there be a leak in thesystem, the gas will settle near the ground. Basements, crawlspaces, skirted

Page 23

3SAFETY PRECAUTIONS

Page 24 - FIGURE 45

30are also available. Consult Maytag Customer Service(1-800-788-8899). Follow manufacturer’s instructions forinstallation of the valves. Before chang

Page 25 - FIGURE 48

31FOR YOUR SAFETY READ BEFORE LIGHTINGWARNING: If you do not follow these instructions exactly, a fire orexplosion may result causing property damage,

Page 26 - Gas Piping

32SERVICE AND MAINTENANCE• Flue gases may escape if vent pipeis not connected.• Be alert for obstructed, sooted ordeteriorated vent system to avoidser

Page 27 - Sediment Traps

33L.P. Gas Control Valve & Burner AssemblyReplacement InformationFor Propane (L.P.) Models OnlyYour water heater is equipped with a Propane (L.P.)

Page 28 - OPERATING INSTRUCTIONS

34NOTE: If the water heater is going to be shut down anddrained for an extended period, the drain valve should beleft open with hose connected allowin

Page 29 - Temperature Regulation

35Start Up ConditionsCondensationWhenever the water heater is filled with cold water, somecondensate will form while the burner is on. A water heater

Page 30 - FIGURE 52

36hot water lines. Contact Maytag Customer Service at1-800-788-8899 for further information concerning an AnodeReplacement Kit and this Chlorination T

Page 31

37Leakage CheckpointsRead this manual first. Then before checking the water heatermake sure the gas supply has been turned “OFF”, and neverturn the ga

Page 32 - SERVICE AND MAINTENANCE

38This troubleshooting guide has been supplied for use by qualified service personnel who have a complete understanding of bothelectricity and gas.Lab

Page 33 - Draining

39PROBLEM SOLUTIONAn open earth ground circuit to the 1. Check that the earth ground connection isignition system. properly connected.2. Check that th

Page 34 - FIGURE 56

4TABLE OF CONTENTSSAFE INSTALLATION, USE AND SERVICE ...

Page 35 - TROUBLESHOOTING

40These guidelines should be used by a qualified Maytag Customer Service Center Agent. Call theMaytag Customer Service Center at 1-800-788-8899 for as

Page 36 - FIGURE 57

41MODEL NO’SHRN11240P 40 Gallon Natural GasHRN31240P 40 Gallon Natural GasHRP11240P 40 Gallon Propane Gas (L.P.)HRP31240P 40 Gallon Propane Gas (L.P.)

Page 37 - Leakage Checkpoints

42MAYTAG GAS WATER HEATERSREPAIR PARTS LISTNow that you have purchased this gas water heater, should a needever exist for repair parts or service, sim

Page 38 - TROUBLESHOOTING (Continued)

43MAYTAG GAS WATER HEATERSREPAIR PARTS LISTMODEL NO’SHRN11275P 75 Gallon Natural GasHRN31275P 75 Gallon Natural GasHRP11275P 75 Gallon Propane Gas (L.

Page 39 - SYSTEM CHECK

4466001010 900240466001011 900160966001012 900160866001013 ETC2X66001014 ETC5X66001015 900240166001020 900073466001021 900158466001025 023012066001027

Page 40

45NOTES

Page 42

47NOTES

Page 43

48FULL ONE YEAR WARRANTYFor one year from the date of original retail purchase, any part which fails in normal home use will be repairedor replaced fr

Page 44

5TANK RECOVERY DIMENSIONSCAPACITY TYPE RATE GALS. VENT PIPE DIAMETER IN INCHES (mm)IN GALS OF BTU PER HOUR INCHES INCHES HEIGHT TOP OFMODEL NUMBER

Page 45

6ACCESSORIES AND TOOLS NEEDEDAccessoriesTo simplify the installation Maytag has available the installation parts shown below. You may or may not need

Page 46

7INSTRUCTIONS FOR INSTALLATION1. Turn “OFF” the gas supply to thewater heater.If the main gas line Shut-off valveserving all gas appliances isused, a

Page 47

8TYPICAL INSTALLATIONGET TO KNOW YOUR WATER HEATER - GAS MODELSA Vent PipeB BlowerC AnodeD Hot Water OutletE Standard Pipe FittingsF Gas SupplyG Manua

Page 48 - WARRANTY

9FIGURE 8.This appliance has been design certified as complying withAmerican National Standard/CSA Standard for water heatersand is considered suitabl

Comments to this Manuals

No comments