FOR POTABLE WATER HEATING ONLY
NOT SUITABLE FOR SPACE HEATING
NOT FOR USE IN
MANUFACTURED (MOBILE) HOMES
Model Numbers
For Your Safety
AN ODORANT IS ADDED TO THE GAS USED
BY THIS WATER HEATER.
GAS WATER HEATER
USER’S GUIDE
Series Twelve
C3 Technology
TM
Gas Water Heaters meet
the new ANSI Z21.10.1 standard that deals
with the accidental or unintended ignition
of flammable vapors, such as those
emitted by gasoline.
HRN11240X
HRP11240X
HRN11250Q
HRP11250Q
HRN11250X
HRP11250X
HRN31240X
HRP31240X
HRN31250Q
HRP31250Q
HRN31250X
HRP31250X
Page view 0
1 2 3 4 5 6 ... 31 32

Summary of Contents

Page 1 - Series Twelve

1www.maytagwaterheaters.comPRINTED IN THE U.S.A. 1204 PART NO. 66001861 184445-001FOR POTABLE WATER HEATING ONLYNOT SUITABLE FOR S

Page 2 - IMPORTANT DEFINITIONS

10Facts to Consider About the LocationCarefully choose an indoor location for the new water heater,because the placement is a very important considera

Page 3 - SAFETY PRECAUTIONS

11Minimum clearances between the water heater andcombustible construction are 0 inch at the sides and rear, 4inches (102 mm) at the front, and 6 inche

Page 4 - TABLE OF CONTENTS

12Combustion Air and Ventilation forAppliances Located in Unconfined SpacesUNCONFINED SPACE is space whose volume is not less than50 cubic feet per 1,

Page 5 - PRODUCT SPECIFICATIONS

13FIGURE 14.• Louvers and Grilles: In calculating free area, considerationshall be given to the blocking effect of louvers, grilles orscreens protecti

Page 6 - ACCESSORIES AND TOOLS NEEDED

14NOTE: To protect against untimely corrosion of hot and coldwater fittings, it is strongly recommended that di-electricunions or couplings be install

Page 7 - INSTRUCTIONS FOR INSTALLATION

15If replaced, the valve must meet the requirements of localcodes, but not less than a combination temperature andpressure relief valve certified as i

Page 8 - TYPICAL INSTALLATION

16• Open the cold water supply valve to the water heater.NOTE: The cold water supply valve must be left open whenthe water heater is in use.• To insur

Page 9

17There must be a minimum of 6 inches (153 mm) clearancebetween single wall vent pipe and any combustible material.Fill and seal any clearance between

Page 10 - LOCATING THE NEW WATER HEATER

18Use pipe joint compound or teflon tape marked as beingresistant to the action of petroleum (Propane [L.P.]) gases.The appliance and its gas connecti

Page 11 - Insulation Blankets

19FOR YOUR SAFETY READ BEFORE LIGHTINGWARNING: If you do not follow these instructions exactly, a fire orexplosion may result causing property damage,

Page 12 - FIGURE 13

2SAFE INSTALLATION, USE AND SERVICEYour safety and the safety of others is extremely important in the installation, use and servicing of this water he

Page 13 - Water Piping

20installation of the valves. Before changing the factory settingon the thermostat, read the Temperature Regulation section inthis manual, see Figure

Page 14 - FIGURE 16

21Tank (Sediment) CleaningSediment build-up on the tank bottom may create varyingamount of noise, if left in the tank will cause permanent tankfailure

Page 15 - Filling the Water Heater

22The burner needs to be removed for cleaning. Call MaytagCustomer Service at 1-800-788-8899 for an authorizedservicer to remove and clean the burner

Page 16 - FIGURE 19

23• Remove the washer and put the new one in place.• Screw the handle and cap assembly back into the drainvalve and retighten using a wrench. DO NOT O

Page 17 - Gas Piping

24Excessive condensation may be noticed during the winter andearly spring months when incoming water temperatures are attheir lowest.Good venting is e

Page 18 - Sediment Traps

25High Temperature Shut Off SystemThis water heater is equipped with an automatic gas Shut-offsystem. This system works when high water temperaturesa

Page 19 - OPERATING INSTRUCTIONS

26These guidelines should be used by a qualified Maytag Customer Service Center Agent. Call the Maytag Customer Service Center at1-800-788-8899 for as

Page 22 - Draining

29MODEL NO’SHRN11240X 40 Gallon Natural GasHRP11240X 40 Gallon Propane Gas (L.P.)HRN11250Q 50 Gallon Natural GasHRP11250Q 50 Gallon Propane Gas (L.P.)

Page 23 - TROUBLESHOOTING

3SAFETY PRECAUTIONS

Page 24 - Operational Conditions

30Key Model Numbers No. Part Description HRN31240X HRP31240X HRN31250Q HRP31250Q HRN31250X HRP31250X1 Air Intake Screen 66001503 66001503 66001503 660

Page 25 - Leakage Checkpoints

3166001011 900160966001012 900160866001013 ETC2X66001014 ETC5X66001015 900240166001016 900240266001021 900158466001020 900073466001105 900276966001183

Page 26 - TROUBLESHOOTING GUIDE

32FULL ONE YEAR WARRANTYFor one year from the date of original retail purchase, any part which fails in normal home use will be repairedor replaced fr

Page 27

4TABLE OF CONTENTSSAFE INSTALLATION, USE AND SERVICE ...

Page 28

5TANK RECOVERY MINIMUM DIMENSIONSCAPACITY TYPE RATE GALS. VENT PIPE DIAMETER IN INCHES (mm)IN GALS OF BTU PER HOUR INCHES INCHES HEIGHT TOP OFMODEL

Page 29 - REPAIR PARTS LIST

6ACCESSORIES AND TOOLS NEEDEDAccessoriesTo simplify the installation Maytag has available the installation parts shown below. You may or may not need

Page 30

7INSTRUCTIONS FOR INSTALLATION1. Turn “OFF” the gas supply to thewater heater.If the main gas line Shut-off valveserving all gas appliances isused, a

Page 31

8TYPICAL INSTALLATIONGET TO KNOW YOUR WATER HEATER - GAS MODELSA Vent PipeB Draft HoodC AnodeD Hot Water OutletE OutletF Standard Pipe FittingsG Gas S

Page 32 - WARRANTY

9FIGURE 8.MIXING VALVE USAGEThis appliance has been design certified as complying withAmerican National Standard/CSA Standard for water heatersand is