SW1 (HEAT) AND SW4 (DELAY) DIP SWITCHES MUST BOTH BE ADJUSTED ACCORDING TO INPUT (NOZZLE SIZE).
NOTE:
Table A-10 ECM Blower Set-Up (POF1HD140AVFA)
DIP SWITCH ADJUSTMENT CHART
FOR INPUT 0.75 USGPH TO 1.00 USGPH
SW1 - HEAT SW2 - COOL
DIP Switch
Position
100-10DD blower with ½ HP ECM
SW2 (COOL): 1 TON is approximately equal to 400 CFM
SW3 (ADJUST): (Heating Mode) Increase OR decrease temperature rise respectively
(Cooling Mode) Increase OR decrease CFM respectively
INPUT DIP Switch Position AC Size
1 2
POS.
USGPH 1 2
POS.
(TON)
OFF OFF A 1.00 OFF OFF A 3
ON OFF B 0.85 ON OFF B 2.5
OFF ON C N/A OFF ON C 2
ON ON D 0.75 ON ON D 1.5
SW3 - ADJUST SW4 - DELAY
DIP Switch
Position CFM DIP Switch Position INPUT
1 2
POS.
1 2
POS.
USGPH
OFF OFF A 0% OFF OFF A 1.00
ON OFF B (+)15% ON OFF B 0.85
OFF ON C (-)15% OFF ON C N/A
ON ON D N/A ON ON D 0.75