Page view 9
Appendix A-
POF1HD140AVFA AND POF1HD091AVFA
Please note: The Beckett AF oil burner is for applications using indoor air for combustion only.
Table A-1 Beckett AF Oil Burner Set-Up
Beckett AF Series Oil Burners
(For use with chimney vented units only)
Furnace Model
Output
BTU/Hr
Burner
Model
Nozzle
Pump
Pressure
Flow
Rate
Head
1
Static
Plate
POF1HD070AVFA ² 59,000 AF76BNHS
0.50 /
80°A
100 psig
0.50
usgph
F3 3- in.
POF1HD091AVFA
76,000 AF76BNHS
0.65 /
80°A
100 psig
0.65
usgph
F3 3- in.
POF1HD105AVFA 87,000 AF76BNHS
0.75 /
80°A
100 psig
0.75
usgph
F3 3- in.
1
Head is shielded by ceramic insulator.
2
Low Firing Rate Baffle required when using a 0.50-gallon
nozzle. Bold models indicate the factory equipped firing rate.
Beckett AF Series Oil Burners
(For use with chimney vented units only)
Furnace Model
Output
BTU/Hr
Burner
Model
Nozzle
Pump
Pressure
Flow
Rate
Head
1
Static
Plate
POF1HD105AVFA 87,150 AF76XN
0.75 /
60°W
100 psig
0.75
usgph
F3 2- ¾ in.
POF1HD119AVFA 98,770 AF76XN
0.85 /
60°W
100 psig
0.85
usgph
F3 2- ¾ in.
POF1HD140AVFA
116,200 AF76XN
1.00 /
60°W
100 psig
1.00
usgph
F3 2- ¾ in.
Bold models indicate the factory equipped firing rate.
10