IDENTIFICATION CODE
Design Series
S = Single Stage
T = Two Stage
Maytag Gas
Compact
PGC 2 T C 090 C 23 B
A = 80% Upflow/Horizontal
C = 92.1% / 95.1% Upflow/Horizontal
K = 80% Downflow
L = 92.1% / 95.1% Downflow
060 = 60,000 100 = 100,000
080 = 80,000 120 = 120,000
C = Standard
D = 90+% AFUE Low NOx
Cooling Airflow
23 = 2-3 Tons
24 = 2-4 Tons
35 = 3-5 Tons
45 = 4-5 Tons
V = VSB
Cabinet Width
B = 17.50
C = 21.00
D = 24.50
SPECIFICATIONS
Input Heating Capacity
*TL 120 is 94.8% AFUE
Note:
All models are 115V, 60 Hz. Gas Connections are 1/2" N.P.T. AFUE = Annual Fuel Utilization Efficiency
(a) Ratings to 2,000 ft. Over 2,000 ft. reduce 4% for each 1,000 ft. above sea level.
PGC2TC/PGC2TL
MODEL NUMBERS:
060D24B 080D35C 100D35C 120D45D
Input - Btuh (a) 60,000 / 39,000 80,000 / 52,000 100,000 / 65,000 120,000 / 78,000
Heating Capacity - Btuh 57,000 / 37,050 76,000 / 49,400 95,000 / 61,750 114,000 / 74,100
AFUE 95.1 95.1 95.1 95.1*
Blower D x W 11 x 8 11 x 10 11 x 10 11 x 10
Motor H.P. - Speed - Type 1/2 - BLDC 3/4 - BLDC 3/4 - BLDC 1 - BLDC
Motor FLA 6.2 8.7 8.7 11.7
Rated Ext. SP - In. W.C. 0.5 0.5 0.5 0.5
Temperature Rise Range - ºF 30-60 35-65 35-65 40-70
Shipping Weights 125lbs 135lbs 145lbs 160lbs
Page view 6
1 2 3 4 5 6 7 8

Comments to this Manuals