16 INSTALLATION INSTRUCTIONS PUBLICATION DATE Nov 05 516828
11. AIRVENT OPENING
On the backside, the washers are provided with an air vent opening of O.D. 75 mm / 3".
WARNING! Watch out, vapors escape from the machine through the air vent opening! Do not cover or
connect to anything!
Do not cover the washer air vent opening. It is part of the back flow prevention water system. It also takes
care that the tub can not be pressurized by water intake and vapor of the hot water, this allows for proper
measuring of the water level.
For the safety of everyone make sure that unauthorized persons cannot reach the backside of the machine.
12. LIQUID SOAPS CONNECTION
The washer has provision for connecting external dosing of liquid soaps. For connecting the liquid soap inlets
and wiring the top panel needs to be opened.
The hoses for liquid soaps are pushed through the holes in the rear panel after removing the plugs. The
hoses should be protected by rubber rings where they are going through the rear panel.
The connection of the liquid soap hoses are made at the rear side of the soap dispenser. By default, these
nipples (max.5) are closed, so it is necessary to drill them out with drill bit 0.2” / 5 mm. Dill only the ones that
will be used for connection to liquid soap hoses. Secure liquid hoses by means of clamps.
WARNING! Check if the hoses are tightened by the clamps! Any leakage of chemicals may cause
injury or corrosion on some of the parts in the machine.
The wiring diagram, is located inside the cabinet on the left or right panel in the plastic bag. On the electronic
control, is a sticker that indicate the availability of 8 liquid soap signals and their position. Fix the input wires
in the matching 9-pole connector in according to the wiring diagram indicated and push him in the “Z”
connector on the electronic controller.
The code number for the matching 9-pole connector can be found in chapter “List of Recommended Parts” at
the end of this manual.
Caution: The first pin is common for the liquid soap signals and of the electronic controller.
The signals are 12V dc and the current must be limited to 10 mA per signal
Never put outside voltage to the pins of the “Z” connector. It will destroy the electronic controller.