RETAIN THESEINSTRUCTIONS IN ASAFE PLACE FORFUTURE REFERENCEMDG30PNH / MDG30MNVInstallation Manual30 lb Single Pocket / Phase 7 / Non-Coinwith Fire Sup
6 Maytag Co. 113307 -7SECTION IIIINSTALLATION PROCEDURESInstallation should be performed by competent technicians in accordance with local and state c
113307- 7 Maytag Co. 74. Provisions for adequate air supply must be provided as noted in this manual (refer to Fresh Air SupplyRequirements in Section
8 Maytag Co. 113307 -7NOTE: Air considerations are important for proper and efficient operation.Dryers may be positioned sidewall to sidewall. Howeve
113307- 7 Maytag Co. 9E. EXHAUST REQUIREMENTSExhaust ductwork should be designed and installed by a qualified professional. Improperly sized ductwor
10 Maytag Co. 113307 -7NOTE 1 Opening must be 2-inches (5.08 cm) larger than the duct (all the way around). The duct must be centered within this ope
113307- 7 Maytag Co. 11MULTIPLE DRYER (COMMON) VENTINGIMPORTANT: For extended ductwork runs, the cross section area of the ductwork can only beincreas
12 Maytag Co. 113307 -7F. ELECTRICAL INFORMATION1. Electrical RequirementsALL electrical connections must be made by a properly licensed and competen
113307- 7 Maytag Co. 13ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER) IMPORTANT: NOTES: A. B.208 VAC AND 240 VAC ARE NOT THE SAME. When ordering,spe
14 Maytag Co. 113307 -7a. Single-Phase (1ø) Wiring Connections/HookupThe electrical input connections on ALL single-phase (1ø)gas dryers are made into
113307- 7 Maytag Co. 15G. GAS INFORMATIONIt is your responsibility to have ALL plumbing connections made by a qualified professional to ensure that t
Retain This Manual In A Safe Place For Future ReferenceThis product embodies advanced concepts in engineering, design, and safety. If this product is
16 Maytag Co. 113307 -7TYPE OF GASNATURAL LIQUID PROPANE Manifold Pressure* 3.5 inches W.C.8.7 mb10.5 inches W.C.26.1 mb In-Line Pressure 6.0 - 12.0
113307- 7 Maytag Co. 173. Piping ConnectionsALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LATESTEDITION,
18 Maytag Co. 113307 -7NOTE: A water column test pressure of 3.5 inches (8.7 mb) for natural gas and 10.5 inches (26.1 mb)for liquid propane (L.P.) dr
113307- 7 Maytag Co. 19I. PREOPERATIONAL TESTSALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational t
20 Maytag Co. 113307 -7NOTE: If computer program changes are required, refer to the computer programming section of themanual supplied with the dryer.
113307- 7 Maytag Co. 21REVERSING TIMER SPIN/DWELL ADJUSTMENTSTimer models have an electronic reversing timer in the electrical service box, which is l
22 Maytag Co. 113307 -7SECTION IVSERVICE/PARTS INFORMATIONA. SERVICEService must be performed by a qualified trained technician, service agency, or g
113307- 7 Maytag Co. 23SECTION VWARRANTY INFORMATIONA. RETURNING WARRANTY CARDS1. Before any dryer leaves the manufacturer’s test area, a warranty ca
24 Maytag Co. 113307 -7SECTION VIROUTINE MAINTENANCEA. CLEANINGA program and/or schedule should be established for periodic inspection, cleaning, and
113307- 7 Maytag Co. 2590 DAYSInspect and remove lint accumulation in customer furnished exhaust ductwork system and from dryer’s internalexhaust duct
IMPORTANTYOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPLY AND THE GASSUPPLY OR THE STEAM SUPPLY BEFORE ANY COVERS OR GUARDS AREREMOVED FROM THE MAC
26 Maytag Co. 113307 -7SECTION VIIDATA LABEL INFORMATIONWhen contacting the Maytag dealer, certain information is required to ensure proper service/pa
113307- 7 Maytag Co. 27SECTION VIIIPROCEDURE FOR FUNCTIONAL CHECKOF REPLACEMENT COMPONENTS1. Microprocessor Controller (Computer) Boarda. Upon complet
28 Maytag Co. 113307 -72. For Models with Direct Spark Ignition (DSI) Module (Type I)Theory of Operation:Start the drying cycle. When the gas burner
113307- 7 Maytag Co. 29The exclusive fire suppression system will extinguish fires that may start in the drying basket (tumbler). A seriesof sensors
30 Maytag Co. 113307 -7INSTALLATION1. RequirementsThe fire suppression system must be supplied with a minimum water pipe size of 1/2” and be provided
113307- 7 Maytag Co. 31WARNING: If the water in the supply line or water solenoid valve freezes, the fire suppression systemwill be INOPERATIVE!!Typic
Part No. 113307 7 - 06/26/08 - 0
WARNINGThe dryer must never be operated with any of the back guards, outer tops, or servicepanels removed. PERSONAL INJURY OR FIRE COULD RESULT.IMPOR
SECTION ISAFETY PRECAUTIONS ...2SECTION IISPECIFI
2 Maytag Co. 113307 -7SECTION ISAFETY PRECAUTIONSWARNING: For your safety, the information in this manual must be followed to minimize the risk offire
113307- 7 Maytag Co. 3WARNING: DO NOT use heat for drying articles that contain plastic, foam, sponge rubber, orsimilarly textured rubber materials.
4 Maytag Co. 113307 -7MAXIMUM CAPACITY (DRY WEIGHT) 30 lbs13.6 kgBASKET (TUMBLER) DIAMETER 32-3/4”83.2 cmBASKET (TUMBLER) DEPTH 25-5/8”65.1 cmBASKET (
113307- 7 Maytag Co. 5NOTE: The manufacturer reserves the right to make changes in specifications at any time withoutnotice or obligation.Specificatio