Service and Maintenance
Venting System Inspection Burner Inspection
At least once a year a visual inspection should be made of the r
AWARNING
venting system.
Youshou|d lookfor:
/ Flooddamageto a_may not be readily
Obstructions which could cause improper venting. The ] visible or immediately detectible. However, over a
combustion and ventilation air flow must not be obstructed, period of time a flooded water heater will create
dangerous conditions which can cause DEATH, SERI-
OUS BODILY INJURY, OR PROPERTY DAMAGE.
Damage or deterioration which could cause improper vent- Contact the Maytag dealer from whom the appli-
ing or leakage of combustion products, ance was purchased or call Maytag Customer Service
at 1-800-788-8899 for an authorized servicer to
replace a flooded water heater. Do not attempt to
Rusted flakes around top of water heater, repair the unit! It must be replaced!
At least once a year a visual inspection should be made of the
_WARNING
main burner and pilot burner. The drawing is for your reference.
Chemical vapor corrosion of the flue and vent sys-
tem may occur if air for combustion contains certain
chemical vapors. Spray can propellants, cleaning sol- You should check for sooting which is not normal and will
vents, refrigerator and air conditioner refrigerants, impair proper combustion.
swimming pool chemicals, calcium and sodium chlo-
ride, waxes, bleach, and process chemicals are typi-
[ ca compounds which are potentially corrosive.
AWARNING __
Obstructed or deteriorated vent systems may pre-
sent a serous hemth r sk or asphyxiat on.
NATURAL OR PROPANE (L.R) GAS BURNER
AWARNING 33,000 TO 52,500 BTUH INPUT
Be sure the vent piping is properly connected to
prevent escape of dangerous flue gasses which
coudcausedeadyasphyxaton. _'_-/_ - /_
AWARNING
If after inspection of the vent system you found NATURALORPROPANE(L.R)GASBURNER
sooting or deterioration, something is wrong. Call s5,000TO 75,000BTUHINPUT
the local gas utility or Maytag Customer Service at
1-800-788-8899 for an authorized servicer to correct
the problem and clean or replace the flue and vent-
ing before resuming operation of the water heater.
Failure to make corrections can result in a fire, or
explosion causing DEATH, SERIOUS BODILY INJURY,
OR PROPERTY DAMAGE.
NATURAL OR PROPANE (L.P.) GAS BURNER
75,100 BTUH INPUT
AWARNING
Soot build-up indicates a problem that requires cor-
rection before further use. Turn "OFF" gas to water
heater and leave "OFF" until repairs are made,
because failure to correct the cause of the sooting
can result in a fire or explosion causing DEATH,
SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.