Maytag Ventilation Systems HRV-210 User Manual Page 24

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 23
24
8.0
Installation of the Controls (con’d)
W R G
Y
W
R
G
C
Y
9
8
7
6
5
4
3
2
1
HRV CONTROL CONNECTOR
THERMOSTAT
TERMINALS
FOUR
WIRES
I OC OL Y R G BF F
J3
TWO WIRES
heating only
FURNACE
24-VOLT
TERMINAL BLOCK
TWO WIRES
COOLING SYSTEM
VE0010A
Standard furnace interlock wiring
8.3 ELECTRICAL CONNECTION TO OPTIONAL CONTROLS
9
8
7
6
5
4
3
2
1
OL
OC
I
1 4 7
2 5 8
3 6 9
J3
MAIN PC BOARD
PUSH-BUTTON SWITCHES
(5 switches maximum)
J1
0L
I
VE0036A
REAR VIEW
8.4 ELECTRICAL CONNECTION TO THE FURNACE
WRGY
W
R
Y
R
G
Y
C
J1
1
2
4
5
6
8
93
*FURNACE INTERLOCK
RELAY
NC NO
7
COM
7
THERMOSTAT
TERMINAL
Unit Control Module
4 WIRES
2 WIRES
heating only
wiring
nuts
FURNACE
24-VOLT
TERMINAL BLOCK
2 WIRES
COOLING SYSTEM
GRAY BROWN
RED
GREEN
BLUE
9-PIN AMP PLUG
*FURNACE INTERLOCK RELAY, PART # 12658
VE0009A
Alternate furnace interlock wiring
For a furnace connected to cooling system:
On some older thermostats, energizing the “R” and “G” terminals at the furnace has the effect of energizing
“Y” at the thermostat and thereby turning on the cooling system. If you identify this type of thermostat, you
must use the “alternate furnace interlock wiring”. An additional control relay will then have to be installed.
WARNING
010
!
Never connect a 120-volt AC circuit to the terminals of the furnace interlock (standard wiring). Only
use the low voltage class 2 circuit of the furnace blower control.