Maytag MGT3800XW Installation Guide

Browse online or download Installation Guide for Washer dryers Maytag MGT3800XW. Maytag MGT3800XW Installation Guide User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
27" (69 CM) GAS WASHER/DRYER
INSTALLATION INSTRUCTIONS
INSTRUCTIONS POUR L’INSTALLATION DE LA LAVEUSE/
SÉCHEUSE À GAZ DE 27" (69 CM)
WASHER/DRYER SAFETY
Table of Contents Table des matiéres
WASHER/DRYER SAFETY .......................................................... 1
INSTALLATION REQUIREMENTS ............................................... 4
Tools and Parts ..................................................................... 4
LOCATION REQUIREMENTS ...................................................... 6
DIMENSIONS/CLEARANCES ..................................................... 7
DRAIN SYSTEM ........................................................................... 8
ELECTRICAL REQUIREMENTS .................................................. 9
GAS SUPPLY REQUIREMENTS .................................................. 9
REMOVE SHIPPING STRAP ...................................................... 11
INSTALL LEVELING LEGS ......................................................... 11
VENTING ..................................................................................... 12
Venting Requirements ........................................................ 12
Plan Vent System ................................................................ 13
Install Vent System ............................................................. 14
CONNECT DRAIN HOSE ........................................................... 15
CONNECT INLET HOSES .......................................................... 16
MAKE GAS CONNECTION ........................................................ 18
CONNECT VENT ........................................................................ 18
LEVEL WASHER/DRYER ........................................................... 19
COMPLETE INSTALLATION CHECKLIST ................................ 20
W10356101C
INSTALLATION NOTES
Date of purchase: _________________________________________
Date of installation: _______________________________________
Installer: _________________________________________________
Model number: ___________________________________________
Serial number: ____________________________________________
Date d’achat: _____________________________________________
Date d’installation: ________________________________________
Installateur: ______________________________________________
Numéro de modéle: _______________________________________
Numéro de série: _________________________________________
NOTES CONCERNANT L’INSTALLATION
SÉCURITÉ DE LA LAVEUSE/SÉCHEUSE ................................21
EXIGENCES D’INSTALLATION ................................................. 24
Outillage et pièces ............................................................. 24
EXIGENCES D’EMPLACEMENT .............................................. 26
DIMENSIONS/DISTANCES DE DÉGAGEMENT ....................... 27
SYSTÈME DE VIDANGE ............................................................ 28
SPÉCIFICATIONS ÉLECTRIQUES ............................................ 29
SPÉCIFICATIONS DE L’ALIMENTATION EN GAZ ................... 29
ENLEVER LA SANGLE D’EXPÉDITION .................................... 31
INSTALLATION DES PIEDS DE NIVELLEMENT ...................... 31
ÉVACUATION .............................................................................32
Exigences concernant l’évacuation ................................. 32
Planication du système d’évacuation ............................ 33
Installation du conduit d’évacuation ................................ 34
RACCORDEMENT DU TUYAU DE VIDANGE ........................... 35
RACCORDEMENT DES TUYAUX D’ARRIVÉE D’EAU ............. 36
RACCORDEMENT À LA CANALISATION DE GAZ .................. 37
RACCORDEMENT DU CONDUIT D’ÉVACUATION .................38
ÉTABLISSEMENT DE L’APLOMB
DE LA LAVEUSE/SÉCHEUSE ....................................................39
LISTE DE VÉRIFICATION POUR L’ACHÈVEMENT
DE L’INSTALLATION .................................................................. 40
Page view 0
1 2 3 4 5 6 ... 39 40

Summary of Contents

Page 1 - INSTALLATION INSTRUCTIONS

27" (69 CM) GAS WASHER/DRYER INSTALLATION INSTRUCTIONS INSTRUCTIONS POUR L’INSTALLATION DE LA LAVEUSE/SÉCHEUSE À GAZ DE 27" (69 CM)WASHER/D

Page 2 - WASHER/DRYER SAFETY

10A. 3/8" exible gas connectorB. 3/8" pipe to are adapter tting C. 1/8" NPT minimum plugged tappingD. 1/2" NPT gas supply lineE

Page 3

11Do not cut yellow strap. Pull yellow strap rmly, until completely removed from washer/dryer. There should be 2 cotter pins on the end of the shippi

Page 4 - INSTALLATION REQUIREMENTS

12VENTINGVenting RequirementsWARNING: To reduce the risk of re, this dryer MUST BE EXHAUSTED OUTDOORS.IMPORTANT: Observe all governing codes and ordi

Page 5 - If you have: You will need:

13Plan Vent SystemRecommended exhaust installationsTypical installations vent the washer/dryer from the rear. Other installations are possible.ABCDEFG

Page 6 - LOCATION REQUIREMENTS

14Vent System ChartNumber of 90° turns or elbowsType of ventBox/louvered hoodsAngled hoods120Rigid metalRigid metalRigid metal37 ft. (11.3 m)32 ft.

Page 7 - DIMENSIONS/CLEARANCES

15Place hose into standpipe (shown in picture) or over side of laundry tub.IMPORTANT: 4.5" (114 mm) of drain hose should be inside standpipe; d

Page 8 - DRAIN SYSTEM

16CONNECT INLET HOSESWasher must be connected to water faucets with new inlet hoses with at washers (not provided). Do not use old hoses.NOTE: Both h

Page 9 - ELECTRICAL REQUIREMENTS

17Turn on water faucets to check for leaks. A small amount of water may enter washer. It will drain later.6. Check for leaksSecure drain hose to laund

Page 10 - GAS SUPPLY REQUIREMENTS

18 AB Open shut-off valve4.Open shut-off valve in supply line; valve is open when handle is parallel to gas pipe. Then, test all connections by brushi

Page 11 - 3. Cut shipping strap

19LEVEL WASHER/DRYERIMPORTANT: Level washer/dryer properly to reduce excess noise and vibration.If washer/dryer is not level, use a 9/16" or 14 m

Page 13 - 4396005 Wall offset elbow

205. Plug into a grounded 3-prong outletCOMPLETE INSTALLATION CHECKLISTq Check that all parts are now installed. If there is an extra part, go back

Page 14 - 1. Install exhaust hood

21SÉCURITÉ DE LA LAVEUSE/SÉCHEUSE

Page 15 - 1. Attach clamp to drain hose

22SÉCURITÉ DE LA LAVEUSE/SÉCHEUSE

Page 17 - 7. Secure drain hose

24Outillage facultatif :Pièces fournies :REMARQUE : Retirer le sachet de pièces du panier de la laveuse. Vérier que toutes les pièces de la liste son

Page 18

25Pièces nécessaires : (Non fournies avec la laveuse/sécheuse)Autres pièces : (Non fournies avec la laveuse/sécheuse)Il se peut que l’installation néc

Page 19 - 3. Tighten leveling feet

26Il vous faudra :nUn emplacement permettant une évacuation appropriée. Une laveuse/sécheuse à gaz doit être dotée d’un circuit de décharge à l’ext

Page 20

27DIMENSIONS/DISTANCES DE DÉGAGEMENT271/4"(692 mm)713/4"(1822 mm)351/4"(895 mm)411/4"(1,048 mm)11"(279 mm)14"(356 mm)1&q

Page 21

28SYSTÈME DE VIDANGELe système de vidange de la laveuse peut être installé à l’aide d’un conduit d’évacuation au plancher, un tuyau de rejet à l’égou

Page 22

29SPÉCIFICATIONS ÉLECTRIQUES SPÉCIFICATIONS DE L’ALIMENTATION EN GAZTYPE DE GAZGaz naturel :Cette sécheuse est équipée pour une alimentation au gaz na

Page 24 - EXIGENCES D’INSTALLATION

30CANALISATION DE GAZ n La canalisation doit comprendre un connecteur obturé (letage NPT de 1/8" ou plus) accessible pour le raccordement de l’i

Page 25

31INSTALLATION DES PIEDS DE NIVELLEMENTRelever l’avant de la laveuse/sécheuse d’environ 4" (102 mm) à l’aide d’un bloc de bois ou autre objet

Page 26 - EXIGENCES D’EMPLACEMENT

32ÉVACUATIONExigences concernant l’évacuationAVERTISSEMENT : Pour réduire le risque d’incendie, cette sécheuse doit ÉVACUER L’AIR À L’EXTÉRIEUR.IMPORT

Page 27 - Distances de dégagement

33Planication du système d’évacuationInstallations d’évacuation recommandéesLes installations typiques consistent à acheminer le conduitd’évacuation

Page 28 - SYSTÈME DE VIDANGE

34Tableau des systèmes d’évacuationNombre de coudes à 90°Type de conduit d’évacuationClapets de type boîte/ à persiennesClapets inclinés120Métalliq

Page 29 - TYPE DE GAZ

35RACCORDEMENT DU TUYAU DE VIDANGEVérier que le tuyau de vidange a la bonne longueur. Mouiller la surface intérieure de l’extrémité rectiligne du tu

Page 30 - Option 2

36Faire couler l’eau par les tuyaux dans l’évier de buanderie, le tuyau de rejet à l’égout ou le seau pendant quelques secondes pour éviter toute obst

Page 31 - DE NIVELLEMENT

37Ouvrir les robinets d’eau pour vérier qu’il n’y a pas de fuite.Une petite quantité d’eau peut entrer dans la laveuse. Elle s’évacuera plus tard.6.

Page 32 - ÉVACUATION

38 AB Ouvrir le robinet d’arrêt4.Ouvrir le robinet d’arrêt de l’alimentation. Le robinet est ouvert lorsque la poignée est parallèle au conduit d’alim

Page 33 - Trousses d’évacuation

39ÉTABLISSEMENT DE L’APLOMBDE LA LAVEUSE/SÉCHEUSEIMPORTANT : L’établissement correct de l’aplomb de la laveuse/sécheuse permet de réduire les nuisanc

Page 34

4Optional tools:Parts supplied: NOTE: Remove parts package from the washer basket. Check that all parts were included.TOOLS AND PARTSGather required t

Page 35 - DE VIDANGE

5. Brancher sur une prise à 3 alvéole reliée à la terre.LISTE DE VÉRIFICATION POUR L’ACHÈVEMENT DE L’INSTALLATIONq Vérier que toutes les pièces so

Page 36 - D’ARRIVÉE D’EAU

5Parts needed: (Not supplied with washer/dryer) Alternate parts: (Not supplied with washer/dryer)Your installation may require additional parts. To or

Page 37

6You will need:nA location that allows for proper exhaust installation. A gas washer/dryer must be exhausted to the outdoors. See “Venting Require

Page 38 - LA CANALISATION DE GAZ

7271/4"(692 mm)713/4"(1822 mm)351/4"(895 mm)411/4"(1,048 mm)11"(279 mm)14"(356 mm)1"(25 mm)25"(635 mm)261/2&qu

Page 39 - DE LA LAVEUSE/SÉCHEUSE

8DRAIN SYSTEMDrain system can be installed using a oor drain, wall standpipe, oor standpipe, or laundry tub. Select method you need.Floor standpipe

Page 40

9ELECTRICAL REQUIREMENTSn This washer/dryer is equipped with a power supply cord having a 3-prong grounding plug.n To minimize possible shock hazar

Comments to this Manuals