• CopelandUltra-TechScrollCompressor: State of the art, two
stage compressor is standard equipment.
• Quiet Operation and Low Vibration: Swept-wing fan blade
combined with custom Venturi condenser fan orifice.
• CompressorSoundBlanket:Is standard equipment.
• WireGuardCoatedwithEarthFriendlyEpoxyandPlasticMesh
HailGuard:A guard that will never rust and protects the units coil
from being damaged.
• Anteater
®
CoilTechnology: For increased resistance against
formicary corrosion, the number one cause of evaporator coil
failures.
• Designed Using Galvanized Steel: With a polyester urethane
coat finish. The 950 hour salt spray finish is 1.5 mil thick and resists
corrosion 50% better than comparable units.
• SmallerPanels,GreatFitandFinish,TotalSeal:Well-designed,
quality construction.
• OnePieceTopPan:With drip edge on top panels whisks away
rainwater.
• EmbossedBottomPan:Keeps blower component compartment dry.
• PermanentlyLubricatedCondenserMotor:A heavy duty PSC
motor for long lasting reliability and quiet operation. Requires no
maintenance and is protected from rain and snow.
• Thermostatic Expansion Valve: Factory installed, externally
equalized thermostatic expansion valve provides precise refrigerant
control under varying load conditions.
• Hi/LowPressureSwitches: Ensure long compressor life.
• ExternallyAccessible,HighFlowServicePorts: Quick access
to refrigeration system.
• LiquidLineFilterDrier: Factory installed at a convenient location
for service.
• Two-StageHeatOperation: Featuring a two stage gas valve and
2 speed inducer motor.
• ChoiceofHeatingControl:Two stage thermostat or single stage
heating thermostat with on the control board timing of 5 or 10 minute
delay for second stage of heat.
• LowVoltageTransformer: Includes 5 Amp fuse to protect low
voltage circuit.
• Corrosion-ResistantDrainPan:Quickly drains away evaporator
condensate.
• ECMVariableSpeedBlowerMotor: Advanced technology allows
the motor to automatically adjust to different static loads. The
variable speed motor allows for extra quiet operation and improved
air quality.
• Heavy-Gauge, Full Perimeter Base Rails: Facilitates forklift
handling and curb mounting.
• ConvertibleAirDelivery: Horizontal or downflow to accommodate
rooftop or horizontal applications.
• Easy Compressor and Control Access: Designed to make
servicing easier for the contractor, access panels are provided to
all controls and the compressor from the side of the unit.
• Easy Access: To the evaporator coil for cleaning and general
maintenance.
• RemovableTopGrilleAssembly:Allows ease of service to the
fan motor.
• DuctFlanges:Reduce installation costs.
• Proven, Industry Standard Components: Easier service and
availability.
• SmartLite
®
ControlBoard:Provides extended life to igniters using
hot surface ignition technology. Programmed to learn the heat-up
characteristics of the igniter, then adapt the ignition time to the
characteristics of the furnace so the igniter is energized appropriately.
• HotSurfaceIgniter:Innovative application of an appliance type
igniter with a 20 year history of reliability.
• Accessories:Roof curbs and more.
R6GF15SEER,81%AFUE
2-5TonUnits
R6GFSeriesRevB
SinglePackagedGas/ElectricUnits
Two-StageHeat/CoolwithVariable
SpeedBlower
These single packaged gas/electric systems are high
efficiency self contained heating and cooling units that
can be installed on the roof or on a slab. The convertible
unit design makes installations simple in all applications.
Units are ETL listed.
FEATURESandBENEFITS
TECHNICAL
SPECIFICATIONS
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - R6GFSeriesRevB

• CopelandUltra-TechScrollCompressor: State of the art, two stage compressor is standard equipment. • Quiet Operation and Low Vibration: Swe

Page 2 - MODELIDENTIFICATIONCODE

10R6GF-X60KB-HIGHSPEED  O.D.T 65°F 75°F 85°F 95°F 105°F 115°FCFM E.D.B.E.W.B. T. C .  S.C. K.W. T. C .  S.C. K.W. T. C .  S.C.

Page 4 - SINGLEPHASE

388E-0215Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illust

Page 5 - AIRFLOWDATA

2TopViewDIMENSIONSMODELIDENTIFICATIONCODER6 GF-X24K 080XBApplicati

Page 6 - R6GFACCESSORIES

3BackViewSideViewDIMENSIONS(Continued)12.4512.454.0 D8.75HorizontalSupply DuctOpeningHorizontalReturn DuctOpening4.01.759.75 24.7516.0CondensingCo

Page 7 - EXPANDEDRATINGS

4SPECIFICATIONSANDELECTRICALDATASINGLEPHASEMODEL R6GF-X24K080XB R6GF-X36K100XB R6GF-X48K120XB R6GF-X60K120XBHeating Input High/Low Btuh 80,000 / 5

Page 8

5AIRFLOWDATAHeatingAirowSettingsCoolingAirowSettings ModelNumberHeatingInput(Btuh)HeatingOutput(Btuh)CFMRangeHeatingRiseRange(°F)Cooling

Page 9

6R6GFACCESSORIESDescription PartNumberRoof Curb (8”) 547830Roof Curb (14”) 547831Roof Curb (18”) 547850Roof Curb (24”) 547851Cap, Duct Adapter, 12”

Page 10 - EXPANDEDRATINGS(CONTINUED)

7EXPANDEDRATINGSO.D.T 65°F 75°F 85°F 95°F 105°F 115°FCFM E.D.B.E.W.B.  T . C .  S.C. K.W. T. C .  S.C. K.W. T. C .  S.C. K.W. T

Page 11

8EXPANDEDRATINGS(CONTINUED)R6GF-X36KB-LOWSPEED  O.D.T 65°F 75°F 85°F 95°F 105°F 115°FCFM E.D.B.E.W.B. T. C .  S.C. K.W. T. C .  S.

Page 12 - 388E-0215

9R6GF-X48KB-HIGHSPEED  O.D.T 65°F 75°F 85°F 95°F 105°F 115°FCFM E.D.B.E.W.B. T. C .  S.C. K.W. T. C .  S.C. K.W. T. C .  S.C.

Comments to this Manuals