Maytag MMV5156AAB Dimension Guide User Manual

Browse online or download User Manual for Microwaves Maytag MMV5156AAB Dimension Guide. Maytag MMV5156AAB Dimension Guide User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 3
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Minimum
mounting
height from
cooking
surface
Minimum
mounting
height from
floor
Unit width:
Unit depth:
Unit height:
Recommended opening depth:
Recommended opening width:
Mounting height from floor:
Distance from unit
face to open door:
Wall View (not to scale)
(not to scale)
22"
66" Min.
30"
13"
29 15/16"
15 3/8"
16 7/16"
22"
66" Min.
30"
13"
29 15/16"
15 3/8"
16 7/16"
Exhaust outlet
connects to
3 1/4" X 10" duct
Door Open
Minimum mounting height
from cooking surface:
30"
30"
• Electrical requirements: Voltage 120, single phase,
60Hz. AC. 20 Amp. 2 wire with ground circuit required.
Locate outlet box in the cabinet above in the lower right
hand corner, cut a 2" hole in the back right hand corner
of the cabinet above for the units cord.
• Wall construction should be a minimum of 2"x4" wood
studding and 3/8" thickness drywall or plaster/lath.
• Units are designed for use above all non-grilling gas
and electric ranges and cooktops (not recommended
over grill-ranges or cooktops with grilling capability
unless the range or cooktop is equipped with downdraft
ventilation).
• Outside ventilation requires hood exhaust duct. The
hood exhaust has been designed to mate with a
standard 3 1/4" x 10" duct. If round is required, a
transition adaptor must be used. Do not use less than
6" round duct.
• Maximum duct length: The total duct length of 3 1/4" x
10" rectangular or 6" round duct should not exceed 140
equivalent feet. When calculating the total duct length
add equivalent lengths of all transitions and adaptors
plus the lengths of all straight duct sections.
• 220 Hi/ 110 Low CFM Vertical exhaust (3 1/4" x 10"
duct).
• 220 Hi/ 110 Low CFM Horizontal exhaust (3 1/4" x 10"
duct).
See page 2 for additional information
www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600
• Dimensions (Actual Size) •
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
Over the Range Microwaves:
MMV5156AAB, MMV5156AAQ, MMV5156AAS and
MMV5156AAW
• Product Model Number (s): •
Subject to change without notice. This system is designed to
be updated daily if necessary. Dimension Express is not
responsible for use of superseded, voided, or outdated data
sheets. Because of the difficulty or impracticability of deter-
mining actual damages, liability of Dimension Express shall
not exceed $50.00.
Copyright © Dimension Express, 2002.
This Data Sheet Includes Information On
BN220.78 • A191B278C150 • • 032603 • 95659 • 85243
• Additional Information •
191
Maytag
Page view 0
1 2 3

Summary of Contents

Page 1

Minimummountingheight fromcookingsurfaceMinimummountingheight fromfloorUnit width:Unit depth:Unit height:Recommended opening depth:Recommended opening

Page 2 - DIMENSION EXPRESS

• Equivalent lengths of typical duct adaptors: 3 1/4" x 10" 45° elbow =5 feet straight. 3 1/4" x 10" 90° elbow = 25 feet strai

Page 3

12"4"1/2"6"1/2"4"12 "6"Center LineDuct cutout locations (not to scale)Upper cabinetVertical DischargeHorizonta