Maytag HRX40HARS User Manual

Browse online or download User Manual for Water boiler Maytag HRX40HARS. Maytag HRX40HARS User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
1
PRINTED IN THE U.S.A 0405 PART NO. 184388-002
66001907
FOR POTABLE WATER HEATING ONLY
NOT SUITABLE FOR SPACE HEATING
NOT FOR USE IN
MANUFACTURED (MOBILE) HOMES
Model Numbers
For Your Safety
AN ODORANT IS ADDED TO THE GAS USED
BY THIS WATER HEATER.
GAS WATER HEATER
USER’S GUIDE
Series Ten
C3 Technology
®
Gas Water Heaters meet
the new ANSI Z21.10.1 standard that deals
with the accidental or unintended ignition
of flammable vapors, such as those
emitted by gasoline.
HRX40YARS
HRX40HARS
HRX40YART
HRX40HART
HRX40YQRT
HRX40HQRT
HRX50YART
HRX50HART
HRX50YQRT5
HRX50HQRT5
HRX50YQRT
HRX50HQRT
Page view 0
1 2 3 4 5 6 ... 31 32

Summary of Contents

Page 1 - Series Ten

1PRINTED IN THE U.S.A 0405 PART NO. 184388-002 66001907FOR POTABLE WATER HEATING ONLYNOT SUITABLE FOR SPACE HEATINGNOT FOR USE INMAN

Page 2 - IMPORTANT DEFINITIONS

10Facts to Consider About the LocationCarefully choose an indoor location for the new water heater,because the placement is a very important considera

Page 3 - SAFETY PRECAUTIONS

11Minimum clearances between the water heater andcombustible construction are 0 inch at the sides and rear, 4inches (102 mm) at the front, and 6 inche

Page 4 - TABLE OF CONTENTS

12Combustion Air and Ventilation forAppliances Located in Unconfined SpacesUNCONFINED SPACE is space whose volume is not less than50 cubic feet per 1,

Page 5 - PRODUCT SPECIFICATIONS

13 FIGURE 14.• Louvers and Grilles: In calculating free area, considerationshall be given to the blocking effect of louvers, grilles orscre

Page 6 - ACCESSORIES AND TOOLS NEEDED

14NOTE: To protect against untimely corrosion of hot and coldwater fittings, it is strongly recommended that di-electricunions or couplings be install

Page 7 - INSTRUCTIONS FOR INSTALLATION

15If replaced, the valve must meet the requirements of localcodes, but not less than a combination temperature andpressure relief valve certified as i

Page 8 - TYPICAL INSTALLATION

16the right (clockwise). The drain valve is on the lower front ofthe water heater.• Open the cold water supply valve to the water heater.NOTE: The col

Page 9

17There must be a minimum of 6 inches (153 mm) clearancebetween single wall vent pipe and any combustible material.Fill and seal any clearance between

Page 10 - LOCATING THE NEW WATER HEATER

18Use pipe joint compound or teflon tape marked as beingresistant to the action of petroleum (Propane [L.P.]) gases.The appliance and its gas connecti

Page 11 - Insulation Blankets

19FOR YOUR SAFETY READ BEFORE LIGHTINGWARNING: If you do not follow these instructions exactly, a fire orexplosion may result causing property damage,

Page 12 - FIGURE 13

2SAFE INSTALLATION, USE AND SERVICEYour safety and the safety of others is extremely important in the installation, use and servicing of this water he

Page 13 - Water Piping

20installation of the valves. Before changing the factory settingon the thermostat, read the Temperature Regulation section inthis manual, see Figure

Page 14 - FIGURE 16

21Tank (Sediment) CleaningSediment build-up on the tank bottom may create varyingamount of noise, if left in the tank will cause permanent tankfailure

Page 15 - Filling the Water Heater

22The burner needs to be removed for cleaning. Call a MaytagService Specialist at 1-800-365-0024 for an authorizedservicer to remove and clean the bu

Page 16 - FIGURE 19

23• Remove the washer and put the new one in place.• Screw the handle and cap assembly back into the drainvalve and retighten using a wrench. DO NOT O

Page 17 - Gas Piping

24Excessive condensation may be noticed during the winter andearly spring months when incoming water temperatures are attheir lowest.Good venting is e

Page 18 - Sediment Traps

25High Temperature Shut-Off SystemThis water heater is equipped with an automatic gas Shut-offsystem. This system works when high water temperaturesa

Page 19 - OPERATING INSTRUCTIONS

26These guidelines should be used by a qualified Maytag Service Specialist. Call a Maytag Service Specialist at 1-800-365-0024for assistance. Inform t

Page 20 - Temperature Regulation

27 Key Model Numbers No. Part Description HRX40YARS HRX40HARS HRX40YART HRX40HART HRX40YQRT HRX40HQRT1 Air Intake Screen 9003406 9003406 9003406 9

Page 21 - SERVICE AND MAINTENANCE

28MAYTAG GAS WATER HEATERSREPAIR PARTS LISTBURNER ASSEMBLY Key

Page 22 - Draining

299003638 660015759003638 660015759003639 660015769003643 660018019003644 660015819003647 660018009003648 660015849003649 660015899003649 660015899003

Page 23 - TROUBLESHOOTING

3SAFETY PRECAUTIONS

Page 26 - TROUBLESHOOTING GUIDE

32FULL ONE YEAR WARRANTYFor one year from the date of original retail purchase, any part which fails in normal home use will be repairedor replaced fr

Page 27 - REPAIR PARTS LIST

4TABLE OF CONTENTSSAFE INSTALLATION, USE AND SERVICE ...

Page 28

5Thank You for purchasing a Maytag water heater. Properlyinstalled and maintained, it should give you years of troublefree service. It is strongly sug

Page 29

6ACCESSORIES AND TOOLS NEEDEDAccessoriesTo simplify the installation Maytag has available the installation parts shown below. You may or may not need

Page 30

7INSTRUCTIONS FOR INSTALLATION1. Turn “OFF” the gas supply to thewater heater.If the main gas line Shut-off valveserving all gas appliances isused, a

Page 31

8TYPICAL INSTALLATIONGET TO KNOW YOUR WATER HEATER - GAS MODELSA Vent PipeB Draft HoodC AnodeD Hot Water OutletE OutletF Flexible Water ConnectionsG G

Page 32 - WARRANTY

9FIGURE 8.MIXING VALVE USAGEThis appliance has been design certified as complying withAmerican National Standard/CSA Standard for water heatersand is

Related models: HRX40YART | HRX40YQRT |

Comments to this Manuals

No comments